5 CONNECTING WEB SERVER MODULE TO NETWORK
Item
Network type setting
IP address setting
Automatic network connection setting at start-up
5 - 19
(2) Program example
This section explains programs for connection/disconnection using sequence
programs.
(a)
Program execution environment
1)
Mount the Web server module on Slot "0" of the main base.
2)
Connect the Web server module and the personal computer with a
crossing cable.
Web server module
IP address
Subnet mask : 255.255.255.0
3)
Make the following network setting of the personal computer.
IP address
Subnet mask
4)
Make the following Web server module setting with the Web browser.
(Use the default values for other than the following.)
 System setting (Refer to Section 4.6.3)
5)
After writing the sequence program using GX Developer, power the
programmable controller off and then on or reset the CPU module.
Crossing cable
: 192.168.3.3
IP address
Subnet mask : 255.255.255.0
: 192. 168. 3. 1
: 255. 255. 255. 0
Select "Connecting through LAN or the router.".
Select "Use the following IP address.".
 IP address
: 192. 168. 3. 3
 Subnet mask
: 255. 255. 255. 0
Select "No connection to network at start-up.".
MELSEC-Q
Personal computer
: 192.168.3.1
Set value
5 - 19