6 FUNCTIONS
6 - 110
(a)
Set the notification IP address.
1)
Select the IP address of which the external device will be notified.
Item
Notify the IP address set
in the "System setting"
screen.
Notify the global IP
address obtained from the
router. ( 1)
Notify the following IP
address.
1 When the router is incompatible with UPnP, the Web server module
cannot obtain the global IP address from the router.
Obtain the static global IP address from the Internet service provider,
and specify the obtained IP address at "Use the following IP address."
2)
When "Notify the following IP address." has been selected, set the IP
address in decimal number.
(Example) 192. 168. 3. 3
3)
Set the IP address after consulting the network administrator (person
in change of network planning, IP address management, etc.).
(b)
Specify the notification HTTP port number.
1)
Select the HTTP port number of which the external device will be
notified.
It is recommended to use the default value (80) of the HTTP port
number.
Item
Notify the HTTP port
number set in the
"System setting" screen.
Notify the following HTTP
port number.
2)
When "Notify the following HTTP port number." has been selected, set
the HTTP port number in decimal number.
1024 to 65535: HTTP port number
3)
Set the HTTP port number after consulting the network administrator
(person in change of network planning, IP address management, etc.).
POINT
After changing the settings, make sure to click on the "Save" button.
The settings are updated when the "Update" button on the Setting update screen is
clicked, the programmable controller is powered off and then on, or the CPU
module is reset.
Select this item when notifying the external device of the IP address
set in the system setting. (Refer to Section 4.6.3)
Select this item when connecting through a router.
The WAN side (Internet side) IP address is obtained from the router
and notified.
Select this item when notifying the specified IP address.
Select this item when using the HTTP port number set in the system
setting.
Select this item when using the specified HTTP port number (1024
to 65535).
MELSEC-Q
Description
Description
6 - 110