hit counter script
Download Print this page
Siemens QAW910 Manual

Siemens QAW910 Manual

Room unit
Hide thumbs Also See for QAW910:

Advertisement

Quick Links

Use
C1N2703en
11.07.2006
Synco™900
Room Unit
• Wireless room unit
• RF communication based on KNX standard (868 MHz, bidirectional)
• Operation and display of space heating functions
• Acquisition of the room temperature
• Battery-powered by commercially available 1.5 V batteries
• For integration into the Siemens Synco 900 system
• Selection of room operating mode, timer function and room temperature setpoint
readjustment
• Display of space heating function and status messages
• Acquisition of the room temperature in HVAC plant
• Especially suited for:
− Renovation projects (old buildings, museums, churches, historical buildings, etc.)
− Difficult wall-mounting situations (sandstone, glass, etc.)
− Variable floor plans (different décors, other furniture)
− New houses and buildings
2
QAW910
Building Technologies
HVAC Products
703

Advertisement

loading

Summary of Contents for Siemens QAW910

  • Page 1 • Operation and display of space heating functions • Acquisition of the room temperature • Battery-powered by commercially available 1.5 V batteries • For integration into the Siemens Synco 900 system • Selection of room operating mode, timer function and room temperature setpoint readjustment •...
  • Page 2 Binding The binding is used by the QAW910 to sign on at the central apartment unit, thus ensuring integration into the RF system. The binding process is triggered via the multifunction button. The RF symbol appears on the display.
  • Page 3 (inside the battery compartment) Binding Disconnect device from system Reset to supply state For more detailed information about the functions and operation of the QAW910, refer to the product documentation covering the central apartment unit. Building Technologies Room unit QAW910...
  • Page 4: Mounting Location

    1.5 m above the floor. To ensure that the QAW910 will acquire the room temperature as accurately as possible, the following conditions must be observed: • The QAW910 must not be mounted on an outer wall, not in niches, bookshelves, and not behind doors or curtains •...
  • Page 5: Installation

    Note Mount the QAW910 first and then insert the batteries. Commissioning Prior to commissioning, check to ensure that the QAW910 is correctly fitted to the wall and that the batteries are correctly inserted. Maintenance / The QAW910 is maintenance-free.
  • Page 6 2M2 class 1M2 Elevation above sea level min. 700 hPa, corresponding to max. 3,000 m above sea level Completely mounted Dimensions Dimensions in mm ©2006 Siemens Switzerland Ltd Subject to change Building Technologies Room unit QAW910 CE1N2703en HVAC Products 11.07.2006...