hit counter script

I/O Combined Module; Qh42P I/O Combined Module - Mitsubishi Electric QX10-TS User Manual

I/o module type building block
Table of Contents

Advertisement

4

I/O COMBINED MODULE

4. I/O COMBINED MODULE

4.1 QH42P I/O Combined Module

• When using the module, configure the system according to Section 1.2.3 (2).
• The module uses same I/O numbers for input and output.
For I/O numbers of I/O combined modules, refer to Section 1.2.3.
(1) DC input specifications (positive common type)
Specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
OFF
Response time
ON
Dielectric withstand voltage
Insulation resistance
Noise immunity
Protection degree
Common terminal arrangement
Number of occupied I/O points
Operation indicator
External connections
Applicable wire size
Applicable connector
Applicable connector/terminal block
converter module
Internal current consumption (5VDC)
Weight
1: For the setting method, refer to the Section 1.3.1.
2: Selection of left-hand (F) side provides the first half (X00 to X1F) LED indications, and selection of right-hand (L) side provides the
latter half (Y00 to Y1F) LED indications.
3 : When using A6CON2 or A6CON3, refer to Chapter 7.
4 - 1
Type
1ms/5ms/10ms/20ms/70ms or less (configured in PLC parameter)
ON
1ms/5ms/10ms/20ms/70ms or less (configured in PLC parameter)
OFF
By noise simulator of 500Vp-p noise voltage, 1
32 points (I/O assignment is set as a 32-point I/O combined module.)
ON indication (LED), 32-point switchover using switch
QH42P I/O combined module (input specifications)
32 points
Photocoupler
24VDC (+20/-15%, ripple ratio within 5%)
Approx. 4mA
See the derating chart.
19V or higher/3mA or higher
11V or lower/1.7mA or lower
Approx. 5.6kΩ
(Default: 10ms)
(Default: 10ms)
560VAC rms/3 cycles (altitude 2000m)
10MΩ or more by insulation resistance tester
s noise width and 25 to 60Hz noise frequency
First transient noise IEC61000-4-4: 1kV
IP2X
32 points/common (common terminal: 1B01, 1B02)
40-pin connector
2
0.088 to 0.3mm
(For A6CON1 or A6CON4)
A6CON1, A6CON2, A6CON3, A6CON4 (optional)
A6TBXY36, A6TBXY54, A6TBX70
130mA (TYP, all points ON)
0.20kg
MELSEC-Q
4
1
1
2
3
4 - 1