HP 70301A Installation And Verification Manual
HP 70301A Installation And Verification Manual

HP 70301A Installation And Verification Manual

Tracking generator
Hide thumbs Also See for 70301A:

Advertisement

Quick Links

Installation and Verification Manual
HP 70301A
Tracking Generator
ABCDE
HP Part No. 70301-90039
Printed in USA
June 1992
Edition B.0.0

Advertisement

Table of Contents
loading

Summary of Contents for HP 70301A

  • Page 1 Installation and Verification Manual HP 70301A Tracking Generator ABCDE HP Part No. 70301-90039 Printed in USA June 1992 Edition B.0.0...
  • Page 2 Notice Restricted Rights Legend.
  • Page 3: Limitation Of Warranty

    Certification Warranty Limitation of Warranty Exclusive Remedies Assistance Product maintenance agreements and other customer assistance agreements are available for Hewlett-Packard products. For any assistance, contact your nearest Hewlett-Packard Sales and Service Oce.
  • Page 4: Safety Symbols

    Safety Symbols CAUTION CAUTION CAUTION WARNING WARNING sign denotes a hazard. It calls attention to a procedure which, if not correctly performed or adhered to, could result in injury to the user. Do WARNING not proceed beyond a sign until the indicated conditions are fully understood and met.
  • Page 5: General Safety Considerations

    General Safety Considerations WARNING The instructions in this document are for use by qualified personnel only. To avoid electrical shock, do not perform any servicing unless you are qualified to do so. The opening of covers or removal of parts is likely to expose dangerous voltages.
  • Page 7 Contents 1. General Information Contents-1...
  • Page 8 2. Installation 3. Speci cations 4. Veri cation 5. Troubleshooting Index Contents-2...
  • Page 9 Figures Tables Contents-3...
  • Page 11: General Information

    General Information Introduction HP 70301A Tracking Generator Installation and Veri cation Manual Organization Chapter 1 Topics Safety General Information...
  • Page 12 Description of the HP 70301A Tracking Generator Notation Conventions in this Manual softkeys HARDKEY hardkey NNNNNNNNNNNNNNNNNNNNNNN Firmkey rmkey MENU NNNNNNNNNNNNNNNNNNNNNNN softkey NNNNNNNNNNNNNNNNNNNNNNN SOFTKEY CRT Text Modules Covered by This Manual Serial Numbers General Information...
  • Page 13 Figure 1-1. Typical Serial Number Label Manual Updating Supplement Front Panel and Rear Panel Features Front-Panel Features General Information...
  • Page 14 UNLEVELED 10 MHz-2.9 GHz IN EXT ALC INPUT RF OUTPUT Module Latch Rear-Panel Features 3.6-6.6 GHz LO IN 3.6-6.6 GHz LO OUT 300 MHz IN General Information...
  • Page 15 300 MHz OUT 21.4 MHz IN 21.4 MHz OUT TUNE SPAN IN Mainframe/Module Interconnect General Information...
  • Page 16 Figure 1-2. Front-Panel and Rear-Panel Features General Information...
  • Page 17: Rom Version

    HP 70900 Local Oscillator Firmware MENU NNNNNNNNNNNNNN NNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN Misc more service ROM VERSION Options and Accessories Options W30 Option Option 001 Option 910 HP 70300A/70301A Operation Manual Option 915 Option 098 or Option 099 General Information...
  • Page 18 Accessories Provided with the HP 70301A Table 1-1. Accessories Shipped with the HP 70301A Description Qty CD Part Number Service Kit Initial Inspection General Information...
  • Page 19 Returning Instruments for Service Caution General Information...
  • Page 20 Figure 1-3. Packaging Materials for HP 70001A Mainframe 1-10 General Information...
  • Page 21 Figure 1-4. Packaging Materials for Modules General Information 1-11...
  • Page 22 Electrostatic Discharge Information Caution Figure 1-5. Static-Safe Workstation Reducing ESD Damage PC Board Assemblies and Electronic Components 1-12 General Information...
  • Page 23 Test Equipment Static-Safe Accessories Table 1-2. ESD Accessories Available from HP Sales and Service Offices Description Qty CD HP Part Number General Information 1-13...
  • Page 24 Table 1-3. ESD Accessories Available from HP Computer Supplies Description HP Model Number Sales and Service Offices 1-14 General Information...
  • Page 25 Table 1-4. Hewlett-Packard Sales and Service Offices IN THE UNITED STATES IN AUSTRALIA IN JAPAN California IN CANADA IN PEOPLE'S REPUBLIC OF CHINA Colorado IN FRANCE IN SINGAPORE Georgia IN GERMAN FEDERAL REPUBLIC Illinois IN GREAT BRITAIN IN TAIWAN New Jersey IN OTHER EUROPEAN COUNTRIES IN ALL OTHER LOCATIONS...
  • Page 27: Installation

    Installation Introduction Chapter 2 Topics Module Installation and Removal Installation Installation...
  • Page 28: Address Map

    Note NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN SELECT INSTR NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN ADDRESS MAP Figure 2-1. Module Removal/Replacement Removal Installation...
  • Page 29 Cable Connections Examples Table 2-1. HP 70000 Modular Measurement System Rear-Panel Cables Description HP Part Number CD 1/8 Spans front Installation...
  • Page 30 HP 71210C with HP 70300A and HP 70301A Figure 2-2. Address Map for HP 71400C with HP 70300A and HP 70301A CAUTION Installation...
  • Page 31 Rear-Panel Cable Connections From Cable Flexible LO I/O Cables Flexible System Cables Miscellaneous Cables Installation...
  • Page 32 Figure 2-3. HP 71210C with HP 70300A and HP 70301A Rear Panel Cabling Installation...
  • Page 33 HP-MSIB/HP-IB Addressing element system component Address matrix Address protocol Address switches Modular Measurement System Terminology Functional Terms Element Slave Master Sub-Master Independent Instrument Structural Terms Mainframe Module Stand-Alone Instrument Installation...
  • Page 34 Address Matrix Figure 2-4. The Address Matrix Table 2-2. Decimal Equivalent of Binary Address Column Binary Decimal Figure 2-5. Master/Slave Addressing with Slave Area Defined Installation...
  • Page 35 Address Switches HP 70301A Address Switches Figure 2-6. Typical Address Switch Setting the HP-MSIB Address Switches Note Installation...
  • Page 36 Note 2-10 Installation...
  • Page 37: Specifications

    Specifications Introduction italics Speci cations Typical performance not warranted Characteristics Nominal values Specifications...
  • Page 38 System Specifications and Characteristics HP 71000 MMS Spectrum Analyzer HP 70900 Installation and Veri cation Manual Specifications...
  • Page 39 Amplitude Flatness rel. to 2.7 GHz Vernier Accuracy Total Abs. Accuracy (0 dB attn.) Amplitude Drift < Tracking Generator Feedthrough Note: Systems with preampli ers will not meet this speci cation. < < < < -50 dBm charateristic HP 70900 Installation and Veri cation Manual Specifications...
  • Page 40 Table 3-1. System Specifications and Characteristics (continued) Parameters Speci cations Scalar Dynamic Range Range Repeatability Accuracy < 12.8 GHz 12.8-18 GHz Spectral Purity Phase Noise at 10 kHz o set < Sidebands < < < < 1st LO < < < Harmonic Spurious <...
  • Page 41 < Table 3-2. HP 70301A Input and Output Characteristics, Front Panel Connectors HP 70301A Characteristics < < < < Table 3-3. HP 70301A Input and Output Characteristics, Rear Panel Connectors HP 70301A Characteristics < > Specifications...
  • Page 42 Table 3-4. General Specifications and Characteristics Parameters Speci cations Temperature Operation Storage Weight Dimensions Specifications...
  • Page 43 Verification Introduction HP 71000 Modular Spectrum Analyzer Installation and Veri cation Manual HP 70900B Local-Oscillator-Controlled Modules Note Explanation of Test Descriptions Tested Speci cation HP 70301A Installation and Veri cation Manual Equipment Equipment Setup NNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNN ABORT PROCEED ABORT NNNNNNNNNNNNNNNNNNNNNNN PROCEED Description...
  • Page 44: Test Descriptions

    Test Descriptions Table 4-1. Tracking Generator Operation Verification Tests Operation Veri cation Test Page Verification...
  • Page 45 TG Absolute Amplitude Accuracy (HP 70301A) TG Absolute Amplitude Accuracy (HP 70301A) Tested Specification Equipment Equipment Setup Description In Case of Failure Verification...
  • Page 46 TG Vernier Accuracy (HP 70301A) Tested Specification Equipment Equipment Setup Description In Case of Failure Verification...
  • Page 47 TG Frequency Response (HP 70301A) TG Frequency Response (HP 70301A) Tested Specification Equipment Equipment Setup Description In Case of Failure Verification...
  • Page 48 TG Feedthru (HP 70301A) (using HP 70902A or HP 70903A) Tested Specification Equipment Note Equipment Setup Description Verification...
  • Page 49 TG Feedthru (HP 70301A) In Case of Failure Verification...
  • Page 51: Troubleshooting

    Troubleshooting Introduction Troubleshooting Features 1. Indicator Lights SRC PWR ON/OFF Troubleshooting...
  • Page 52 2. Status Indicators active Status Error Indicator Note Active Indicator Troubleshooting...
  • Page 53 3. Programs a. Power-On Self-Test: NNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNNNNNN State tracking gen SRC POWER MENU b. System Diagnostics: downloadable program downloaded catastrophic failure soft System diag Select Desired System to Test Test Completed Addressing Error Test Aborted Early Troubleshooting...
  • Page 54 Note CAUTION c. Module Veri cation: d. System Performance: e. Spectrum Analyzer Operation Veri cation: Troubleshooting...
  • Page 55 4. Error Messages CAUTIONS Table 5-1. Error Message Grouping Type Numbers HP 71000 Modular Spectrum Analyzer Installation and Veri cation Manual CAUTION HP 70301A Tracking Generator Service Manual Troubleshooting...
  • Page 56 Operating Errors (2000-2999) 2001 Illegal cmd 2002 Illegal parameter 2006 Parm out of range 2008 Output unleveled 2009 Protocol error Hardware Warning Errors (6000-6999) 6000 EAROM unprotected Hardware Broken Errors (7000-7999) 7000 ROM Check error 7002 First LO unleveled Troubleshooting...
  • Page 57 7005 321.4 MHz error 7009 ROM #2 check error 7078 Tune+Span error 7079 Loop unlocked Troubleshooting...
  • Page 59 Index Index-1...
  • Page 60 Index-2...

Table of Contents