hit counter script
Honeywell TRADELINE T8011R Product Data

Honeywell TRADELINE T8011R Product Data

Programmable heat pump thermostat
Hide thumbs Also See for TRADELINE T8011R:

Advertisement

APPLICATION

The T8011R Heat Pump Thermostat provides 24 Vac control
of a two-stage heating and one-stage cooling heat pump
system with manual changeover from heat to cool. First stage
heating and cooling cycle rates are fixed at 3 cph. Second
stage heating cycle rate is selectable at 1, 3, 6 or 9 cph.
Temperature indication can be set for °F or °C.
The T8011R Heat Pump Thermostat is powered directly
through the system transformer.
® U.S. Registered Trademark
Copyright © 2000 Honeywell •
T8011R Programmable
Heat Pump Thermostat
• All Rights Reserved

FEATURES

• Attractive styling complements any decor to the
homeowner's delight.
• Preprogrammed for your convenience.
• Program up to four time periods and temperature
setpoints to complement your lifestyle.
• Programs are permanently held in non-volatile
memory in the event of a power failure.
• Indefinite setpoint temperature hold for added comfort
and energy savings.
• Ease-of-use means fewer homeowner questions and
increased homeowner satisfaction.
• Large temperature display for quick easy readability.
• Conveniently sized thermostat (5-1/2 x 3-1/2) with
optional decorator cover plates (7-3/8 x 5-3/4) make it
easy to install in a variety of locations.
• Keys are located by the display for easy access.
• FAN and SYSTEM switches are located on the lower
edge to eliminate accidental setting changes.
• Easy installation, setup and system checkout saves
time and increases installer productivity.
• Manual changeover from heat to cool eliminates
unexpected system operation.
°
°
F or
C temperature display for added model
flexibility.
• Cooling cycle rate is fixed (3 cph), the standard setting
for compressors, for speedy installation.
• Selectable 2nd stage heating cycle rate (1, 3, 6 or
9 cph). First stage heating cycle rate is fixed at 3 cph.
• Setpoints are permanently held in non-volatile
memory (no batteries required) and retained during
power outages for increased installer and homeowner
convenience.
• Em. Ht. and Aux. Ht. indicators let the homeowner
know when these modes are active.
Application .......................................................................... 1
Features .............................................................................. 1
Specifications ...................................................................... 2
Ordering Information ........................................................... 2
Installation ........................................................................... 3
Installer Setup ..................................................................... 4
Operation ............................................................................ 6
Checkout ............................................................................. 9
Troubleshooting .................................................................. 10
PRODUCT DATA
Contents
68-0196-1

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell TRADELINE T8011R

  • Page 1: Table Of Contents

    Features ................1 Specifications ..............2 Ordering Information ............2 Installation ................3 Installer Setup ..............4 Operation ................6 Checkout ................9 Troubleshooting ..............10 ® U.S. Registered Trademark Copyright © 2000 Honeywell • • All Rights Reserved 68-0196-1...
  • Page 2: Specifications

    Honeywell Inc., 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 (612) 951-1000 In Canada—Honeywell Limited/Honeywell Limitée, 155 Gordon Baker Road, North York, Ontario M2H 3N7. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
  • Page 3: Installation

    Contact your local waste management authority for thermostat; see Wiring section. instructions regarding recycling and the proper disposal of a control. If you have questions, call the Honeywell Customer Response Center at 1-800-468- 1502. 5 FEET [1.5 METERS] M11338 Fig.
  • Page 4: Installer Setup

    T8011R PROGRAMMABLE HEAT PUMP THERMOSTAT KEEP WIRING IN SHADED AREA WALL WALL ANCHORS (2) MOUNTING WALLPLATE SCREWS (2) M12202 Fig. 3. Mounting wallplate to wall. Wiring IMPORTANT Use an 18-gauge maximum wire for wiring the WIRING ENTRANCE T8011R Thermostat. MOUNTING MOUNTING HOLE SCREW HOLE...
  • Page 5 T8011R PROGRAMMABLE HEAT PUMP THERMOSTAT (HOT) THERMISTOR STAGE 2 RELAY SENSOR AUXILARY THERMOSTAT HEAT RELAY LOGIC SYSTEM SWITCH RELAY EM. HT. HEAT CHANGEOVER VALVE HEAT CHANGEOVER COOL VALVE COOL COMPRESSOR STAGE 1 RELAY CONTACTOR COMPRESSOR CONTACTOR HEAT EMERGENCY HEAT RELAY FAN SWITCH FAN RELAY POWER...
  • Page 6: Operation

    T8011R PROGRAMMABLE HEAT PUMP THERMOSTAT 1. Enter Installer Setup. 3. Setting Heat Cycle Rate (see Table 1 for cycle rate keys to options). set the temperature setpoint to 52 °F NOTE: Cycle rate settings are for second stage heat. (11°C). First stage heat and cool are fixed at 3 cph.
  • Page 7 T8011R PROGRAMMABLE HEAT PUMP THERMOSTAT Setting the Current Time and Day 1. To Set Current Time. Press Select twice. Press to set current time. M12591A While setting the current time, the word SET is displayed. H o l d S e l e 2.
  • Page 8 T8011R PROGRAMMABLE HEAT PUMP THERMOSTAT Press Select. Press Select. Press to set Press to set Return temperature. Sleep temperature. M12639B M12629A 6. Sleep 11. End Programming. Press Select. Press Select. End is Press to set displayed. Programming is Sleep time. complete.
  • Page 9: Checkout

    T8011R PROGRAMMABLE HEAT PUMP THERMOSTAT CHECKOUT 1. Slide the SYSTEM switch to Off and the FAN switch to On. The fan should run continuously. CAUTION 2. Slide the FAN switch to Auto. The system turns the fan on and off with the equipment. Damage to Compressor Possible.
  • Page 10: Troubleshooting

    T8011R PROGRAMMABLE HEAT PUMP THERMOSTAT TROUBLESHOOTING T8011 SYMPTOM POSSIBLE CAUSE ACTION HEATING OR COOLING EQUIPMENT • CHECK THAT C TERMINAL IS CONNECTED TO NO AC POWER TO THERMOSTAT. WON'T OPERATE. THE SYSTEM TRANSFORMER COMMON. • CHECK POWER TO HEATING AND COOLING EQUIPMENT –...
  • Page 11 T8011R PROGRAMMABLE HEAT PUMP THERMOSTAT 68-0196–1...
  • Page 12 T8011R PROGRAMMABLE HEAT PUMP THERMOSTAT Home and Building Control Home and Building Control Honeywell Asia Pacific Inc. Honeywell Honeywell Limited-Honeywell Limitée Room 3213-3225 1985 Douglas Drive North 35 Dynamic Drive Sun Hung Kai Centre Golden Valley, MN 55422 Scarborough, Ontario No.

Table of Contents