Variable
Maximum tightening torque of the fixing screws
Cable connection
SIWAREX WL260 SP-S AB is not approved for legal-for-trade operation.
1)
9.1.3
SIWAREX WL260 SP-S CA
Table 9-3
Variable
Type series
Designation
Construction type
Possible applications
Rated load E
Maximum platform size
Accuracy class according to OIML R60
Max. scale interval n
Min. scale interval V
Combined error F
Creep error F
30 min
Temperature coefficient
Characteristic value T
Zero signal T
Min. initial loading E
Maximum working load L
Break load L
Maximum lateral load L
Rated measuring path h
Recommended supply voltage
Maximum supply voltage
Rated characteristic value C
Tolerance of zero signal D
Input resistance R
Output resistance R
Insulation resistance R
Rated temperature range B
Operating temperature range B
Storage temperature range B
Sensor material
SIWAREX WL200
Operating Instructions, 12/2021, A5E02199611B-13
Technical specifications SIWAREX WL260 SP-S CA
max
LC
min
comb
cr
Kc
Ko
min
u
d
lq
at E
n
max
Rated
o
i
o
is
tn
t
ts
9.1 Functional data
Value
35 ... 40 Nm
Six-core, shielded PVC cable
3 m
Value
WL260
SP-S CA
Single-point load cell
Platform scales and belt scales
150, 250, 500, 1000 kg
600 x 800 mm
C3
3000
E
/ 10000
max
±0.02% C
n
≤ ±0.016% C
n
≤ ±0.011% C
/ 10 K
n
≤ ±0.015% C
/ 10 K
n
0 kg
150% E
max
300% E
max
200% E
max
0.13 mm
5 ... 12 V DC
18 V DC
2.0 ± 0.2 mV/V
< ±1.5% C
n
400 ± 20 Ω
350 ± 3.5 Ω
≥ 5000 MΩ at 50 V DC
-10 to +40 °C
-35 to +65 °C
-35 to +65 °C
Alloyed steel
Technical data
51