hit counter script

Removing Air Inlets; Fig. 32: Removing The Air Inlets - ABB Power2 550-M44 Operation Manual

Hide thumbs Also See for Power2 550-M44:
Table of Contents

Advertisement

Operation Manual / Power2 550-M / High-pressure stage
9 Disassembly and assembly / 9.5 Removing air inlets
9.5

Removing air inlets

Mark the casing position for assembly.
u
Fig. 32: Removing the air inlets
1. Loop the lifting gear around the radial air suction branch (82000).
2. Loosen hexagon-head screws (72013) and remove with washers (72014).
3. Remove the bellows (82300) together with the radial air suction branch (82000) or the
axial air suction branch (82000) with the O-ring (82010), respectively.
Measure clearance N (see
u
© Copyright 2022 ABB. All rights reserved.
Measuring radial clearances N and R
HZTL4058_EN
→91).
Rev.F
March 2022

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt004041

Table of Contents