hit counter script
Download Print this page
Honeywell MultiPRO TB7100A1000/U Manual

Honeywell MultiPRO TB7100A1000/U Manual

Multispeed and multipurpose thermostat for conventional, heat pump, fan coil and ptac systems

Advertisement

Quick Links

TB7100A1000 MultiPRO™
Multispeed and Multipurpose Thermostat
FOR CONVENTIONAL, HEAT PUMP, FAN COIL AND PTAC SYSTEMS
APPLICATION
The TB7100A1000 MultiPRO™ Multispeed and Multipurpose
Thermostat is an effortless, seven-day programmable or non-
programmable thermostat that provides universal system
compatibility, precise comfort control and is easy-to-program.
The TB7100 provides temperature control for gas, oil, electric,
heat pumps, PTACs, and fan coil equipment for the following
types of applications:
— 1H/1C conventional
— Up to 2H/1C heat pump
— 4 pipe fan coil (3 fan speeds)
— 2 pipe fan coil (3 fan speeds)
— 2 pipe fan coil with Auxiliary Heat (3 fan speeds)
— PTAC (Hi, Lo fan speed)
FEATURES
• Large, clear display with backlight shows the current
and set temperature and time—even in the dark.
• Menu-driven programming make setup effortless.
• Beautiful ergonomic design is smart and sophisticated
to match your customers' lifestyle.
• Real-time clock keeps time during power failures and
automatically updates to daylight savings.
• "Saving Changes" notification lets you know when the
schedule changes have been saved.
• Change reminders let you know when to replace the
batteries.
• Holiday Override options allow you to override the
program schedule, as desired.
• Speedy same-schedule programming—no need to
copy multiple days.
• Armchair programming allows you to remove the
thermostat from the wall for programming.
• Programmable or non-programmable modes.
• Remote setback input for occupancy sensors or
timeclocks.
• VersaSpeed™ fan ramping algorithm and fan reset
algorithm (fan coil and PTAC applications).
• Up to 3 fan speeds for fan coil and 2 speeds for PTAC
applications.
• Remote indoor air sensing option (20K ohm or 10K
ohm).
Application ........................................................................
Specifications ...................................................................
Ordering Information ........................................................
Installation ........................................................................
Wiring ...............................................................................
Installer Setup .................................................................. 11
Operation .......................................................................... 17
Troubleshooting (Table 12) ............................................... 23
PRODUCT DATA
Contents
1
2
2
4
5
63-2675-01

Advertisement

loading

Summary of Contents for Honeywell MultiPRO TB7100A1000/U

  • Page 1 TB7100A1000 MultiPRO™ Multispeed and Multipurpose Thermostat FOR CONVENTIONAL, HEAT PUMP, FAN COIL AND PTAC SYSTEMS PRODUCT DATA FEATURES • Large, clear display with backlight shows the current and set temperature and time—even in the dark. • Menu-driven programming make setup effortless. •...
  • Page 2 If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory). 2. Honeywell Customer Care...
  • Page 3 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT NOTE: Alkaline batteries keep calendar and time if lithium battery is no longer functional. Resistance Characteristics of Remote Sensors: C7189U Remote Indoor Sensor: 10K ohm NTC. C7772 Flush-Mount Remote Indoor Sensor: 20K ohm NTC. TR21 Wall-Mount Remote Indoor Sensor: 20K ohm NTC.
  • Page 4 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT 4-5/8 (117) 5 FEET [1.5 METERS] 1-1/8 M22258 2-3/4 (70) (29) Fig. 5. Select thermostat location. FRONT VIEW SIDE VIEW M4465 Do not install the thermostat where it can be affected by: Fig. 4. C7189U Indoor Sensor dimensions in in. (mm). —...
  • Page 5 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT WALL WIRES THROUGH WALL AND WIRE SLOT WALL ANCHORS (2) MOUNTING M13666 HOLES WIRE HOLE Fig. 9. Insert wires into terminal block. M13665 MOUNTING 4. Push excess wire back into the wall opening and restrict SCREWS (2) wires to the shaded area.
  • Page 6 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Table 5. Terminal Designation Descriptions. NOTES: When used in a single-transformer system, leave Terminal metal jumper wire in place between Rc and R. If Designation Description used on a two-transformer system, remove metal Power for cooling—connect to secondary side jumper wire between Rc and R.
  • Page 7 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Heat Pump System Wiring (HOT) (HOT) 24 VAC 24 VAC INDOOR TEMPERATURE HEAT RELAY SENSOR/REMOTE SETBACK CHANGEOVER VALVE INDOOR TEMPERATURE POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD SENSOR/REMOTE PROTECTION AS REQUIRED. COMPRESSOR CONTACTOR SETBACK FACTORY INSTALLED JUMPER.
  • Page 8 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Fan Coil System Wiring (HOT) (HOT) 24 VAC 24 VAC TWO PIPE HEAT/COOL RELAY INDOOR TEMPERATURE LOW FAN RELAY HEAT RELAY SENSOR/REMOTE SETBACK/CHANGEOVER PIPE SENSOR INDOOR TEMPERATURE COOLING RELAY MEDIUM FAN RELAY SENSOR/REMOTE HIGH FAN RELAY SETBACK LOW FAN RELAY POWER SUPPLY.
  • Page 9 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Installing Batteries 1. Install two AA alkaline batteries on the back of the ther- (HOT) mostat as marked. See Fig. 23. 24 VAC BATTERIES (2) BATTERY HOLDER CHANGEOVER VALVE INDOOR TEMPERATURE SENSOR/REMOTE COMPRESSOR CONTACTOR SETBACK LOW FAN RELAY HIGH FAN RELAY...
  • Page 10 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Wire Indoor Sensor SUBBASE CAUTION TR21 Electrical Interference (Noise) Hazard. Can cause erratic system operation. Keep wiring at least one foot away from large inductive loads such as motors, line starters, lighting ballasts and large power distribution panels.
  • Page 11 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT 3. The Setup Number displays to the center of the screen. It is a four-digit code beginning with zero. The current UP AND DOWN MONTH YEAR setting is displayed to the right. BUTTONS CHANGES NOTE: To cycle through the Setup Numbers, press the up or MONTH, down arrow.
  • Page 12 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT INSTALLER SETUP NUMBERS (ISU), SETTINGS, AND TESTS (TABLE 6) Use the Installer System Test to test the heating, cooling and IMPORTANT fan. Refer to the latter portion of Table 6. Use Installer System Test to test heating, cooling and fan.
  • Page 13 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Table 6. Installer Setup Menu. (Continued) Installer Setup Installer Setup Default Number Name Setting All Settings Notes 0310 Deadband 3°F 2 (1.5)—2°F (1.5°C) Only shown if Automatic Changeover selected (ISU 0300). (2°C) 3 (2.0)—3°F (2.0°C) 4 (2.5)—4°F (2.5°C) 5 (3.0)—5°F (3.0°C) 6 (3.5)—6°F (3.5°C)
  • Page 14 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Table 6. Installer Setup Menu. (Continued) Installer Setup Installer Setup Default Number Name Setting All Settings Notes 0349 Auto Fan Reset 0—Inactive The timer will be set after the user selects the constant fan speed. Fan will be set to Auto 1—Reset back to Auto after 2 hours automatically when time out.
  • Page 15 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Table 6. Installer Setup Menu. (Continued) Installer Setup Installer Setup Default Number Name Setting All Settings Notes 0700 Temperature -3 (-1.5)— -3°F (-1.5°C) This offset applies to both the control temperature Display Offset -2 (-1.0)— -2°F (-1.0°C) and to the display temperature for indoor sensor (and -1 (-0.5)—...
  • Page 16 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT PROGRAMMING Table 7 shows default program settings. Table 7. Energy Star Default Program Settings. Setpoints Schedule Period Time Heat Cool Select Day Occ1 8:00am 70°F (21°C) 75°F (24°C) Next Step Cancel Unocc1 10:00pm 55°F (10°C) 85°F (29.5°C) Occ2 —...
  • Page 17 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT OPERATION sensor enabled, the thermostat screen system mode will lock on heat or cool (whatever the changeover sensor is communicating to the thermostat). If ISU #340 does not have a changeover sensor enabled, then the system mode from the Fan Sequence Operations (ISU 347, 348, 349) thermostat screen can manually be adjusted between heat or If heat pump or conventional application modes are enabled in...
  • Page 18 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Table 10. Sequence of Operations for Fan Coil Systems. System Setting Fan Setting Call for Action Energize Terminals Screen Message Off/Cool/Heat/Em Heat/Auto Auto Cool or Auto Auto 4 Pipe Cooling Cool On Y, G , G2 , G3 Cool or Auto...
  • Page 19 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Special Programmable Mode Functions OVERRIDE Changes temperature setting until the next period takes effect. Installer Setup 160 allows the thermostat to be configured for For use during Unoccupied periods. either a mode with a programmable 7 day schedule or as a 1.
  • Page 20 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Replace the batteries as follows: NOTE: If connected to an installed remote indoor temperature 1. Remove the thermostat from the base by pulling it sensor, the thermostat internal sensor is not used. straight out. (See Fig. 39.) ONE REMOTE INDOOR SENSOR INSTALLED 2.
  • Page 21 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT — Users cannot make changes to the temperature setpoint or The C7189U can be used to provide one remote sensor input any schedule, system, or fan settings. or as a temperature averaging network with multiple TR21 —...
  • Page 22 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT 20K OHM AT F (25 TEMPERATURE (DEGREES) M5874A Fig. 41. 20K ohm sensor resistance versus temperature. 63-2675—01...
  • Page 23 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT TROUBLESHOOTING (TABLE 12) Table 12. Troubleshooting. Symptom Possible Cause Action Display does not come on. Thermostat is not being powered. Check for 24 Vac between C and Rc. Check that AAA batteries are installed correctly and are good.
  • Page 24 See www.dtsc.ca.gov/hazardouswaste/perchlorate By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys’...