Type Summary - Siemens OpenAir GEB 1 Series Manual

Air damper actuators
Hide thumbs Also See for OpenAir GEB 1 Series:

Advertisement

Type summary

GEB....
Control type
Operating voltage
AC 24 V
Operating voltage
AC 230 V
Positioning signal Y
DC 0...10 V
DC 2...10 V
DC 0...35 V with characteristic
function Uo, U
Position indicator
U = DC 0...10 V
Feedback potentiometer 1k
Self-adaptation of
rotary angle range
Auxiliary switches (two)
Rotary direction switch
Powerpack (two actuators,
tandem-mounted)
Functions
Type
Control type
Positioning signal with adjustable
characteristic function
Rotary direction
Position indication: Mechanical
Position indication: Electrical
Auxiliary switch
Self-adaptation of
rotary angle range
Powerpack
Rotary angle limitation
Ordering
Note
Delivery
2/6
Siemens
Building Technologies
131.1E
132.1E
136.1E
Three-position control
X
X
X
X
X
X
X
X
GEB13..1 / GEB33...1
Three-position control
Clockwise or counter-clockwise direction depends...
...the type of control. With no power applied, the
actuator remains in the respective position.
Rotary angle position indication by using a position indicator.
The feedback potentiometer can be
connected to external voltage to indicate
the position.
The switching points for auxiliary switches A and B can be set independent of each other
Mounting two of the same actuator types on the
same damper shaft may result in a double torque.
The rotary angle of the shaft adapter can be limited mechanically at increments of 5°.
Potentiometer and cannot be added in the field. For this reason, order the type that
includes the required options.
Individual parts such as position indicator and other mounting materials for the actuator
are not mounted on delivery.
Air damper actuators GEB...1, rotary version
331.1E
332.1E
336.1E
X
X
X
X
X
X
X
X
DC 0...35 V with
Offset
span
...the DIL switch setting clockwise / counter-
clockwise
Position indicator:
Output voltage U = DC 0...10 V is generated
proportional to the rotary angle. U depends on the
rotary direction of the DIL switch.
in increments of 5° within 0° to 90°.
When self-adaptation is active, the actuator
automatically determines the mechanical end
positions of the rotary angle range and maps the
characteristic function (Uo, U) to the calculated
rotary angle range.
Not permitted.
161.1E
163.1E
164.1E
Modulating control
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
GEB16..1
Modulating control
Uo = 0...5 V and
U = 2...30 V
CM2N4621en
166.1E
X
X
X
X
X
X
X
2016-01-29