Operation Manual / 4 Product description / A130-H.. - A140-H
7 Eliminating malfunctions / 7.5 Speed measurement system
7.5
Speed measurement system
No signal or poor signal amplitude of the speed measurement
Possible causes
Turbochar-
The speed sensor was acci-
ger
dentally fitted with an addi-
tional gasket.
An enlarged distance
between the sensor tip and
the signal-emitting sealing
disc reduces the voltage
amplitude of the speed sig-
nal.
Sensor or cable defective
Table 26: Malfunction of the speed measurement system – No signal or poor signal amplitude
Measured speed too high
Possible causes
Turbochar-
Sensor tip contaminated,
ger
since it is magnetic and can
attract metallic particles.
This reduces the distance to
the signal-emitting sealing
disc, which can lead to amp-
lification of the noise com-
ponent and, hence, to false
triggering.
Table 27: Malfunction of the speed measurement system – Measured speed too high
Measured speed too low
Possible causes
Turbochar-
- -
ger
Table 28: Malfunction of the speed measurement system – Measured speed too low
If none of the measures described above remedy the malfunction, have the speed measure-
ment system checked by an ABB Turbocharging Service Station.
© Copyright 2017 ABB. All rights reserved.
Remedy
The screw plug for the sensor is fitted with an
additional gasket (copper ring).
For information regarding the disassembly and
assembly of the speed sensor, refer to chapter
Replacing the speed sensor
Install the speed sensor without the additional
gasket (copper ring).
Contact an ABB Turbocharging Service Station.
Order new speed sensor (86505) (refer to
chapter
Ordering spare parts
Replacing the speed sensor
Remedy
For information regarding the disassembly and
assembly of the speed sensor, refer to chapter
Replacing the speed sensor
Dismantle the sensor, clean the sensor tip, and
fit the sensor back on with the specified tighten-
ing torque.
Remedy
Contact ABB Turbocharging Service Station
HZTL4030_EN
→30.
→87).
→30.
→30.
Revision D
May 2017