9.37

[Control DI 7 (Obj. 2D07h)]

[Control DI 7 (Obj. 2D07h: 00h)]

Data Type
Access
U16
RW
Supported firmware version
ECT
A5
Description
The input device status is returned and set. Refer to "Bit definition of Control DI" in the following manual.
MR-J5-G-N1/MR-J5W-G-N1 User's Manual (Communication Function)
9.38

[Control DI 8 (Obj. 2D08h)]

[Control DI 8 (Obj. 2D08h: 00h)]

Data Type
Access
U16
RW
Supported firmware version
ECT
A5
Description
The input device status is returned and set. Refer to "Bit definition of Control DI" in the following manual.
MR-J5-G-N1/MR-J5W-G-N1 User's Manual (Communication Function)
9.39

[Control DI 9 (Obj. 2D09h)]

[Control DI 9 (Obj. 2D09h: 00h)]

Data Type
Access
U16
RW
Supported firmware version
ECT
A5
Description
The input device status is returned and set. Refer to "Bit definition of Control DI" in the following manual.
MR-J5-G-N1/MR-J5W-G-N1 User's Manual (Communication Function)
Mapping
Default
RxPDO
0000h
Mapping
Default
RxPDO
0000h
Mapping
Default
RxPDO
0000h
Range
Units
0000h to FFFFh
Range
Units
0000h to FFFFh
Range
Units
0000h to FFFFh
9 Manufacturer Specific Control Object
9.37 [Control DI 7 (Obj. 2D07h)]
Save
Parameter
Impossible
Save
Parameter
Impossible
Save
Parameter
Impossible
121
9