9.16
[Fault prediction status (Obj. 2C29h)]
[Fault prediction status (Obj. 2C29h: 00h)]
Data Type
Access
U32
RO
Supported firmware version
ECT
A5
Description
The friction failure prediction status is returned.
[Bit 0 to 3: Friction failure prediction status]
0: Friction failure prediction disabled
1: During preparation for friction failure prediction
2: During execution of friction failure prediction
3: During friction failure prediction warning
[Bit 4 to 7: Vibration failure prediction status]
0: Vibration failure prediction disabled
1: During preparation for vibration failure prediction
2: During execution of vibration failure prediction
3: During vibration failure prediction warning
[Bit 8 to 11: Total travel distance failure prediction status]
0: Motor total travel distance failure prediction disabled
1: Motor total travel distance failure prediction being executed
2: Motor total travel distance failure prediction at warning
[Bit 12 to 15: Motor total travel distance calculation status]
0: During stop of motor total travel distance calculation
1: During calculation of motor total travel distance
[Bit 16 to 19: reserved]
[Bit 20 to 23: Static friction failure prediction status]
0: Static friction failure prediction disabled
1: During preparation for static friction failure prediction
2: During execution of static friction failure prediction
3: During static friction failure prediction warning
[Bit 24 to 27: Belt tension deterioration prediction status]
0: Belt tension deterioration prediction disabled
1: Belt tension deterioration prediction in progress
2: During belt tension deterioration warning
[Bit 28 to 31: Belt tension estimation status]
0: Belt tension estimation in progress
1: Belt tension estimation has finished
7: Belt tension estimation is not set
9 Manufacturer Specific Control Object
108
9.16 [Fault prediction status (Obj. 2C29h)]
Mapping
Default
Impossible
Range
Units
00000000h to
FFFFFFFFh
Save
Parameter
Impossible