Figure 18
DC Power Supply Terminal Block Plastic Cover (ASR1013/06-PWR-DC)
1
2
3
Before you continue to install the terminal block ground wires, stop and perform Step 5. To prevent any contact
Caution
with metal lead on the ground wire and the plastic cover.
Wrap the positive and negative lead cables with sleeving. Take each lead wire and cover the area from the lug to the
Step 3
wire with heavy shrink sleeving.
See
Figure 15
if you are using the ASR1006-PWR-DC power supply.
See
Figure 16
if you are using the ASR1013/06-PWR-DC power supply.
For easier cable-management, insert the negative lead cable first. Replace the ground lug with cable in the following
Step 4
order:
a. Flat Washer
b. Ground lug with negative wire
c. Kepnut screw
Figure 19
shows these elements in the ASR1006-PWR-DC power supply.
22
5
Negative terminal
Positive terminal
Terminal block plastic cover
1
2
-4 8 /- 6 0 V
4 0 A