hit counter script

Cisco Router ASR 1006 Hardware Installation Manual page 22

Cisco systems router quick start guide
Hide thumbs Also See for Router Cisco ASR 1006:
Table of Contents

Advertisement

Figure 18
DC Power Supply Terminal Block Plastic Cover (ASR1013/06-PWR-DC)
1
2
3
Before you continue to install the terminal block ground wires, stop and perform Step 5. To prevent any contact
Caution
with metal lead on the ground wire and the plastic cover.
Wrap the positive and negative lead cables with sleeving. Take each lead wire and cover the area from the lug to the
Step 3
wire with heavy shrink sleeving.
See
Figure 15
if you are using the ASR1006-PWR-DC power supply.
See
Figure 16
if you are using the ASR1013/06-PWR-DC power supply.
For easier cable-management, insert the negative lead cable first. Replace the ground lug with cable in the following
Step 4
order:
a. Flat Washer
b. Ground lug with negative wire
c. Kepnut screw
Figure 19
shows these elements in the ASR1006-PWR-DC power supply.
22
5
Negative terminal
Positive terminal
Terminal block plastic cover
1
2
-4 8 /- 6 0 V
4 0 A
T h is u n it
m ig h t h a v
e m o re th
a n o n e p o
w e r s u p p ly
4
3
4
5
— —
c o n n e c ti o
n . A ll c o n
n e c ti o n s m
u s t b e re m
o v
Plastic cover slotted area
Terminal block plastic cover single screw

Advertisement

Table of Contents
loading

Table of Contents

Save PDF