Verifying Power Supply Operation
Follow this procedure to verify that the power supply is operating correctly in the Cisco ASR 1006 Router.
Step 1
Check that the power supply LEDs are:
• INPUT OK is green
• FAN OK is green
• OUTPUT FAILED is not illuminated
Step 2
To ensure that the power supply state is OK, type the show platform command. This output sample is from a Cisco
ASR1006 router. The other Cisco ASR1000 routers display similar type of output.
MCP_SCAL_R1#sho plat
Chassis type: ASR1006
The following output displays:
Slot
Type
1
ASR1000-SIP10
1/1
SPA-8X1GE-V2
2
ASR1000-SIP10
2/0
SPA-1X10GE-L-V2 ok
2/1
SPA-8X1GE-V2
R0
ASR1000-RP1
F0
ASR1000-ESP20
P0
ASR1006-PWR-AC
P1
ASR1006-PWR-AC
Slot
CPLD Version
1
07091401
2
07091401
R0
08060301
F0
08041102
MCP_SCAL_R1#
If the LEDs indicate a power problem or the power supply state is ps,fail, then contact a customer service representatives for
assistance or additional instructions.
24
State
Insert Time
ok
00:03:19
ok
00:02:23
ok
00:03:19
00:02:22
ok
00:02:17
ok,active 00:03:19
ok,active 00:03:19
ok
00:02:50
ps, fail
00:02:50
Firmware
Version
12.2(33r)XN2
12.2(33r)XN2
12.2(0:0)
12.2(33r)XN2