Rack-Mounting the Switch
•
•
Required Installation Tools
The following tools and equipment are required to install the chassis:
•
•
•
The following tools and equipment are required to install the chassis in a rack:
•
•
Rack-Mounting the Catalyst 4900M Switch
Follow these steps to install the Catalyst 4900M switch in a four-post rack.
Step 1
Prepare for installation:
a.
b.
c.
d.
Table 3-1
Quantity
1
1
2
12
8
8
Cisco Catalyst 4900M Switch Installation Guide
3-4
Keep your back straight and lift with your legs, not your back. If you must bend down to lift the
chassis, bend at the knees, not at the waist, to reduce the strain on your lower back muscles.
Always disconnect all external cables before lifting or moving the chassis.
Number 1, number 2 Phillips, and 3/16-inch flat-blade screwdriver
Antistatic mat or antistatic foam
Your own ESD grounding strap or the disposable ESD strap included with the system
Rack-mount kit
Tape measure and level
Place the chassis on the floor or on a sturdy table as close as possible to the rack. Leave enough
clearance to allow you to move around the chassis.
Use a tape measure to measure the depth of the rack. Measure from the outside of the front mounting
posts to the outside of the rear mounting strip. The four-post rack depth must be at least 19.25 inches
(48.9 cm) but not more than 32.5 inches (82.5 cm). If the 4-post rack depth is greater than
32.5 inches (82.5 cm), order and use the optional rack-mount kit (C4900M-BKTS-KIT=).
Measure the space between the inner edges of the left front and right front mounting posts to ensure
that it is 17.75 inches (45.09 cm) wide. (The chassis is 17.5 inches [44.5 cm] wide and must fit
between the mounting posts.)
Open the standard rack-mount kit, and refer to
Standard Rack-Mount Kit Checklist
Part Description
Left mounting bracket
Right mounting bracket
Rear mounting brackets
M4 Phillips Flat-head screws
12-24 x 3/4-inch Phillips binder-head screws
10-32 x 3/4-inch Phillips binder-head screws
Chapter 3
Table 3-1
to verify that all parts are included.
Received
Installing the Switch