Figure 6-9
The "Settings - Communication" menu item, "OPC UA" tab
OPC UA basic settings
In the "OPC UA basic settings" area, you can enable/disable the communication via the OPC
UA interface and make basic settings for the OPC UA interface.
Table 6- 14
Parameter
Parallel
Lost events
Application name
Default port
SIMATIC RF360R
Configuration Manual, 03/2022, C79000-G8976-C629-02
Description of the OPC UA basic parameters
Description
When the check box is selected, e@Mattin parallel diagnostic access via the
OPC UA channel can be enabled in addition to an existing connection, e.g. to a
controller (PLC). In the case of parallel access, please note that the OPC UA
client only has read access to the reader. If access to the communications
module already takes place from another application at the same time, this
option cannot be selected.
If the function is disabled, access to the reader can only take place over a
communication channel. If a connection is already established over a
communication channel, an additional connection attempt from another
communication channel is rejected.
If the check box is selected, a lost event is generated each time a transponder
leaves the antenna field.
Name of the OPC UA application of the server. The application name is required
to identify the OPC UA namespace of the reader and should be unique for each
reader within the project.
The application name is part of the URL of the OPC UA server of the reader.
Here you can change the port number of the application. As default, port
number 4840 is used, the standard TCP port for the OPC UA binary protocol.
Configuring with the WBM
6.3 The menu items of the WBM
53