hit counter script

Mitsubishi Electric MELSERVO-J5 User Manual page 320

Ac servo system
Hide thumbs Also See for MELSERVO-J5:
Table of Contents

Advertisement

Servo parameter [B]
Servo
Symbol
parameter
PF80.0
DRMC
PF80.2-3
DRMC
PF81.0
DRMS
PF82.0
DRTM
PF82.1
DRTM
PF82.2
DRTM
PF82.3
DRTM
PF83.0
**DRTAX
PF84.0-1
DRTC
PF84.2-3
DRTC
PF84.4-5
DRTC
PF85
DRTL1
PF86
DRTL2
PF87.0-2
DRAC1
4 APPLICABLE FUNCTIONS
318
4.6 Drive recorder
Name
Drive recorder - Operation mode selection
Drive recorder - Sampling cycle selection
Drive recorder - Sampling start selection
Drive recorder - Trigger mode selection
Drive recorder - Trigger binding condition selection
Drive recorder - Trigger operation selection 1
Drive recorder - Trigger operation selection 2
Drive recorder - Trigger axis common selection
Drive recorder - Trigger channel selection 1
Drive recorder - Trigger channel selection 2
Drive recorder - Trigger position setting
Drive recorder - Trigger level setting 1
Drive recorder - Trigger level setting 2
Drive recorder - Analog channel 1 selection
Outline
Select the operation mode of drive recorder.
0: Automatic setting mode (initial value)
1: Manual setting mode
Set the sampling cycle.
00: Automatic (250 μs) (initial value)
05: 250 μs
06: 500 μs
07: 1 ms
08: 2 ms
09: 4 ms
0A: 8 ms
0B: 16 ms
0C: 32 ms
0D: 64 ms
0E: 128 ms
0F: 256 ms
10: 512 ms
11: 1.024 s
Select to start sampling in manual setting mode.
0: Stop sampling (initial value)
1: Start a single sampling
2: Start a consecutive sampling
Select the trigger mode.
0: Alarm trigger (initial value)
1: Analog trigger/digital trigger
Select the binding condition of the trigger.
0: Disabled (initial value)
1: Logical AND of trigger signals
2: Logical OR of trigger signals
Select if sampling starts when the channel set in [Pr. PF84.0-1
Drive recorder - Trigger channel selection 1] exceeds the set
trigger level (rising) or starts when it falls below the set trigger
level (falling).
0: Rising (initial value)
1: Falling
Select if sampling starts when the channel set in [Pr. PF84.2-3
Drive recorder - Trigger channel selection 2] exceeds the set
trigger level (rising) or starts when it falls below the set trigger
level (falling).
0: Rising (initial value)
1: Falling
For a multi-axis servo amplifier, select whether to store only the
data of the axis in which the conditions are met or to store the
data of all axes when using the manual setting mode and the
trigger conditions are met on an analog trigger or digital trigger.
0: Disabled (initial value)
1: Enabled
Set trigger channel No. 1.
Initial value: 01h (Analog channel 1)
Set trigger channel No. 2.
Initial value: 81h (Digital channel 1)
For the total sampling time, set the trigger position in
hexadecimal from 0 to 100 %.
Initial value: 5Ah (90 [%])
Set the trigger level of [Pr. PF84.0-1 Drive recorder - Trigger
channel selection 1] in decimal.
Initial value: 0
Set the trigger level of [Pr. PF84.2-3 Drive recorder - Trigger
channel selection 2] in decimal.
Initial value: 0
Set the data to be assigned to analog channel 1.
Initial value: 201h (Servo motor speed +)
*1