Positioning operation
■Operation procedure
Transmit the command, data No., and data as follows to execute positioning operation.
When LSP/LSN was turned Off by external input
signal
Enable input device.
Command
: [9] [2]
Data No.
: [0] [0]
Data
: 00000007
(SON, LSP, and LSN turned on.)
*1 A delay of 100 ms.
9 COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC AC SERVO PROTOCOL) [A]
532
9.5 Detailed explanations of commands
Start
Command
: [8] [B]
Data No.
: [0] [0]
Data
: 0002 (Positioning operation)
Servo motor speed setting
Command
: [A] [0]
Data No.
: [1] [0]
Data
: Write the speed [r/min] in
hexadecimal.
Acceleration/deceleration time constant setting
Command
: [A] [0]
Data No.
: [1] [1]
Data
: Write the acceleration/deceleration
time constant [ms] in hexadecimal.
Travel distance setting
Command
: [A] [0]
Data No.
: [2] [0]
Data
: Write the travel distance [pulse] in
hexadecimal.
Rotation direction selection
Command
: [A] [0]
Data No.
: [2] [1]
Data
: 0000 (Forward rotation direction)
0001 (Reverse rotation direction)
When LSP/LSN was turned On by external input
signal or automatically
Command
Data No.
Data
*1
Start positioning operation
Command
: [A] [0]
Data No.
: [4] [0]
Data
: 1EA5
End
Command
: [8] [B]
Data No.
: [0] [0]
Data
: 0000
(Test operation mode is canceled.)
Enable input device.
: [9] [2]
: [0] [0]
: 00000001
(SON turned on.)
Select the JOG operation in the test
operation mode.
Set the operation pattern.
Ready for operation (servo-on)
Start
Test operation mode is canceled.

Advertisement