■Copy and paste of point table data (h)
Click "Copy" to copy the selected point table data. Click "Paste" to paste the copied point table data.
■Inserting point table data (i)
Click "Insert" to insert one block before the selected point table number. The blocks after the selected point table number are
shifted down by one block.
■Deleting point table data (j)
Click "Delete" to delete all the data on the selected point table number. The blocks after the selected point table number are
shifted up by one block.
■Point table data change (k)
Select the data to be changed, enter the new value, and confirm with the Enter key. The display range and unit can be
changed with "Point table data detailed setting (f)".
■Reading point table data (l)
Click "Open" to read the point table data.
■Saving point table data (m)
Click "Save As" to save the point table data.
■Updating the project (n)
Click "Update Project" to update the point table of the project.
Description of the detailed setting window
The speed and acceleration/deceleration unit can be changed in the detailed setting.
For the settings of [Pr. PT01.1 Speed/acceleration/deceleration unit selection], check the next "Point table".
Page 543 Point table
Click "Update Project" in the point table window to apply the settings to the corresponding parameters.
(a)
(b)
■Setting speed and acceleration/deceleration unit (a)
Select the unit of speed from r/min, mm/s, or command unit/s.
The unit of acceleration/deceleration is automatically selected to ms or command unit/s
■Setting of position data unit (b)
Select the unit of position data from mm, inch, degree, or pulse.
2
according to the unit of speed.