Contents Chapter 1: About this document....................8 Chapter 2: System overview......................9 Front view of the system..............................9 Rear view of the system..............................11 Inside the system................................14 Locating the Express Service Code and Service Tag....................18 System information label..............................18 Rail sizing and rack compatibility matrix........................21 Chapter 3: Technical specifications.....................
Page 4
System Setup..................................38 System BIOS.................................39 iDRAC Settings utility..............................55 Device Settings................................55 Dell Lifecycle Controller..............................55 Embedded system management..........................55 Boot Manager..................................55 PXE boot..................................... 56 Chapter 6: Minimum to POST and system management configuration validation......57 Minimum configuration to POST ..........................57 Configuration validation..............................57 Error messages................................
Page 5
Side and center bracket perfect sealing.........................81 Removing the side wall bracket..........................82 Installing the side wall bracket..........................83 Cable routings..................................84 PERC module..................................93 Removing the front mounting front PERC module..................... 93 Installing the front mounting front PERC module....................94 Removing the rear mounting front PERC module....................95 Installing the rear mounting front PERC module....................
Page 6
Installing the intrusion switch..........................156 Optional OCP card................................157 Removing the OCP card............................157 Installing the OCP card............................158 Control panel..................................159 Removing the right control panel.......................... 159 Installing the right control panel..........................160 Removing the left control panel..........................161 Installing the left control panel..........................162 Power supply unit................................
Page 7
NIC indicator codes................................191 Power supply unit indicator codes..........................191 Drive indicator codes..............................193 Using system diagnostics.............................. 193 Dell Embedded System Diagnostics........................194 Chapter 14: Getting help......................195 Recycling or End-of-Life service information......................195 Contacting Dell Technologies............................195 Accessing system information by using QRL......................196 Chapter 15: Receiving automated support with SupportAssist ..........
About this document This document provides an overview about the system, information about installing and replacing components, diagnostic tools, and guidelines to be followed while installing certain components. About this document...
● Up to 10 x 2.5-inch SAS/SATA/NVMe drives or 8 x 2.5-inch NVMe SSD drives or 4 x 3.5-inch SATA/SAS drives or 2 x 2.5-inch (rear) SAS/SATA (HDD/SSD) drives. NOTE: For more information about how to hot swap NVMe PCIe SSD U.2 device, see the Dell Express Flash NVMe PCIe SSD User's Guide at https://www.dell.com/support >...
Page 10
Table 1. Features available on the 4 x 3.5-inch drive system (continued) Item Ports, panels, and Icon Description slots Right control panel Contains the power button with integrated power LED, 1 x VGA port, 1 x 2.0 USB port, iDRAC Direct (Micro-AB USB) port, and the iDRAC Direct status LED.
OCP card which is connected to the system board. Dedicated iDRAC9 Ethernet Enables you to remotely access iDRAC. For more information, port see the Integrated Dell Remote Access Controller User's Guide at www.dell.com/poweredgemanuals. VGA port Enables you to connect a display device to the system.
Page 12
OCP card which is connected to the system board. Dedicated iDRAC9 Ethernet Enables you to remotely access iDRAC. For more information, port see the Integrated Dell Remote Access Controller User's Guide at www.dell.com/poweredgemanuals. VGA port Enables you to connect a display device to the system.
Page 13
Icon Description Dedicated iDRAC9 Ethernet Enables you to remotely access iDRAC. For more information, port see the Integrated Dell Remote Access Controller User's Guide at www.dell.com/poweredgemanuals. Coolant tubes Enables you to install the coolant tubes for Direct Liquid Cooling feature.
Inside the system Figure 7. Inside the system without Risers 1. Cooling fan cage assembly 2. Fan power connector 3. Processor 4. System board 5. Guiding mechanism to guide Riser module 6. Rear I/O board 7. Power Supply Units (PSU 1 and 2) 8.
Page 15
11. Drive backplane with latch 12. Information Tag Figure 8. Inside the system with Risers 1. Cooling fan cage assembly 2. Fan power connector 3. Processor 4. Latch mechanism to engage Riser module 5. Guiding mechanism to guide Riser module 6.
Page 16
Figure 9. Inside the system with Risers + Rear 2 x 2.5-inch module 1. Cooling fan cage assembly 2. Fan power connector 3. Processor 4. Latch mechanism to engage Riser module 5. Guiding mechanism to guide Riser module 6. Riser 3 7.
Page 17
Figure 10. Inside the system with Direct Liquid Cooling 1. Cooling fan cage assembly 2. Fan power connector 3. Liquid cooling module 4. System board 5. Coolant tubes 6. Coolant tube/sensor cable holder 7. Power Supply Units (PSU 1 and 2) 8.
The Mini Enterprise Service Tag (MEST) label is located on the rear of the system that includes Service Tag (ST), Express Service Code (Exp Svc Code), and Manufacture Date (Mfg. Date). The Exp Svc Code is used by Dell EMC to route support calls to the appropriate personnel.
Page 19
Figure 12. Service information Figure 13. Memory information System overview...
Page 20
Figure 14. LED behavior Figure 15. Icon legend Figure 16. System tasks Figure 17. Fan System overview...
Figure 18. Express service tag Rail sizing and rack compatibility matrix For specific information about the rail solutions compatible with your system, see the Dell Enterprise Systems Rail Sizing and Rack Compatibility Matrix available at https://i.dell.com/sites/csdocuments/Business_solutions_engineering- Docs_Documents/en/rail-rack-matrix.pdf. The document provides the information that is listed below: ●...
Technical specifications The technical and environmental specifications of your system are outlined in this section. Topics: • Chassis dimensions • System weight • Processor specifications • PSU specifications • Supported operating systems • Cooling fan specifications • System battery specifications •...
Table 9. PowerEdge R6615 processor specifications Supported processor Number of processors supported AMD EPYC 4 Generation 9004 Series processor PSU specifications The PowerEdge R6615 system supports up to two AC or DC power supply units (PSUs). Table 10. PSU specifications Class Heat Frequenc Voltage...
● Microsoft Windows Server with Hyper-V ● Red Hat Enterprise Linux ● SUSE Linux Enterprise Server ● VMware ESXi For more information, go to www.dell.com/ossupport. Cooling fan specifications The PowerEdge R6615 system supports up to four high performance gold (HPR Gold) cooling fans. Technical specifications...
The PowerEdge R6615 system uses one CR 2032 3.0-V lithium coin cell battery. Expansion card riser specifications The PowerEdge R6615 system supports up to three PCI express (PCIe) (two Full Height or three Low Profile Gen 4/Gen 5 capable + OCP) Gen5 slots on the system board.
Front PERC (Gen (Gen 1 (Gen NOTE: The expansion-card slots are not hot-swappable. Memory specifications The PowerEdge R6615 system supports the following memory specifications for optimized operation. Table 15. Memory specifications Single Processor DIMM type DIMM rank DIMM capacity Minimum system...
● 2 x 2.5-inch hot-swappable SAS, SATA rear drives ● Zero drive NOTE: For more information about how to hot swap NVMe PCIe SSD U.2 device, see the Dell Express Flash NVMe PCIe SSD User's Guide at https://www.dell.com/support >Browse all Products > Data Center Infrastructure > Storage Adapters &...
Ports and connectors specifications USB ports specifications Table 18. PowerEdge R6615 USB specifications Front Rear Internal (optional) USB port type No. of ports USB port type No. of ports USB port type No. of ports USB 2.0- USB 3.0- Internal USB 3.0-...
On the system board, the supported OCP PCIe width is x8; when x16 PCIe width is installed, it is downgraded to x8. Serial connector specifications The PowerEdge R6615 system supports one optional card type serial connector, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant .
Video specifications The PowerEdge R6615 system supports integrated Matrox G200 graphics controller with 16 MB of video frame buffer. Table 20. Supported video resolution options Resolution Refresh rate (Hz) Color depth (bits) 1024 x 768 8, 16, 32 1280 x 800...
Page 31
Table 23. Continuous Operation Specifications for ASHRAE A4 Temperature Specifications Allowable operation Temperature range for altitudes <= 900 m (<= 5 to 45°C (41 to 113°F) with no direct sunlight on the equipment 2953 ft) Humidity percent range (non-condensing at all 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) times) maximum dew point...
Table 27. Particulate contamination specifications (continued) Particulate contamination Specifications NOTE: Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive particles NOTE: This condition applies to data center and non-data center environments.
Page 33
Table 30. Air cooling: Thermal restriction matrix (non-GPU) (continued) 8 x 2.5- 4 x 3.5- 10 x 2.5- Configuration No BP 10 x 2.5-inch SAS inch U.2 inch inch NVMe Rear storage No Rear No Rear No Rear 2.5-inch No Rear No Rear Drives Drives Drives...
CPU TDP > 200W are not supported Memory 128GB and higher capacity RDIMMS are not supported. PCIe card Non-Dell qualified peripheral cards and consuming power greater than 25W are not supported GPU cards are not supported Rear storage Not Supported...
Initial system setup and configuration This section describes the tasks for initial setup and configuration of the Dell system. The section also provides general steps to set up the system and the reference guides for detailed information. Topics: • Setting up the system •...
Ensure that you change the default username and password after setting up the iDRAC IP address. For more information about logging in to the iDRAC and iDRAC licenses, see the latest Integrated Dell Remote Access Controller User's Guide at www.dell.com/idracmanuals.
Ensure that you clear the web browser cache before downloading the drivers and firmware. Steps 1. Go to www.dell.com/support/drivers. 2. Enter the Service Tag of the system in the Enter a Dell Service Tag, Dell Product ID or Model field, and then press Enter. NOTE: If you do not have the Service Tag, click Browse all products, and navigate to your product.
UEFI (Unified Extensible Firmware Interface). You can enable or disable various iDRAC parameters by using the iDRAC settings utility. For more information about this utility, see Integrated Dell Remote Access Controller User’s Guide at www.dell.com/ poweredgemanuals.
System BIOS To view the System BIOS screen, power on the system, press F2, and click System Setup Main Menu > System BIOS. Table 37. System BIOS details Option Description System Information Provides information about the system such as the system model name, BIOS version, and Service Tag.
Page 40
Table 38. System Information details (continued) Option Description System CPLD Version Specifies the current version of the system complex programmable logic device (CPLD) firmware. UEFI Compliance Version Specifies the UEFI compliance level of the system firmware. AGESA Version Specifies the AGESA reference code version. SMU Version Specifies the SMU firmware version.
Page 41
Table 40. Processor Settings details (continued) Option Description IOMMU Support Enable or Disable IOMMU support. It is required to create IVRS ACPI table. This option is set to Enabled by default. Kernel DMA Protection When this option is set to Enabled, using IOMMU, BIOS, and the Operating System will enable direct memory access protection for DMA capable peripheral devices.
Page 42
Table 40. Processor Settings details (continued) Option Description Configurable TDP Allows the reconfiguration of the processor Thermal Design Power (TDP) levels based on the power and thermal delivery capabilities of the system. TDP refers to the maximum amount of power the cooling system is required to dissipate. This option is set to Maximum by default.
Page 43
Dell Qualified NVMe drives always use the UEFINVMe driver built into the Dell EROS. When this option is set to 'All Drives', the BIOS driver will also be used with any NVMe drives in the system that has not been qualified by Dell. The option is set to Dell Qualified Drives by default.
Page 44
Operating systems must be UEFI-compatible to be installed from the UEFI boot mode. DOS and 32-bit operating systems do not support UEFI and can only be installed from the BIOS boot mode. NOTE: For the latest information about supported operating systems, go to www.dell.com/ossupport. Changing boot order About this task You may have to change the boot order if you want to boot from a USB key or an optical drive.
Page 45
2. Use the arrow keys to select a boot device, and use the plus (+) and minus (-) sign keys to move the device down or up in the order. 3. Click Exit, and then click Yes to save the settings on exit. NOTE: You can also enable or disable boot order devices as needed.
Page 46
Table 48. HTTP Device n Settings details (continued) Option Description Prefix Length: IPv6 Prefix Length (0-128) for this HTTP Device. VLAN Enables VLAN for HTTP device. This option is set to Enable or Disable. This option is set to Disable by default. VLAN ID Shows the VLAN ID for the HTTP device VLAN Priority...
Page 47
Integrated Devices To view the Integrated Devices screen, power on the system, press F2, and click System Setup Main Menu > System BIOS > Integrated Devices. Table 52. Integrated Devices details Option Description User Accessible USB Ports Configures the user accessible USB ports. Selecting Only Back Ports On disables the front USB ports;...
Page 48
Table 52. Integrated Devices details (continued) Option Description system initializes the timer. When this option is set to Disabled (the default), the timer does not have any effect on the system. Memory Mapped I/O Limit Controls where MMIO is mapped. The 1 TB option is designed for specific OS which cannot support MMIO over 1 TB.
Page 49
Table 53. Serial Communication details (continued) Option Description setup utility may not always revert this setting to the default setting of Serial Device 1. Failsafe Baud Rate Specifies the failsafe baud rate for console redirection. The BIOS attempts to determine the baud rate automatically. This failsafe baud rate is used only if the attempt fails, and the value must not be changed.
Page 50
Table 54. System Profile Settings details (continued) Option Description Power Profile Select High performance Mode(default): Favors core performance. All DF P-States are available in this mode and the default DF P-State and DLWM algorithms are active. Efficiency Mode: Configures the system for power efficiency. Limits boost frequency available to cores and restricts DF P-States available in the system.
Page 51
Table 56. System Security details (continued) Option Description When set to Enabled, the storage and endorsement hierarchies can be used. When set to Disabled, the storage and endorsement hierarchies cannot be used. When set to Clear, the storage and endorsement hierarchies are cleared of any values and then reset to Enabled.
Page 52
Table 56. System Security details (continued) Option Description If the current Table 57. Secure Boot Mode mode is set to User Mode, the Options Descriptions available options User In User Mode, PK must be installed, and BIOS are User Mode, Mode performs signature verification on programmatic Audit Mode, and...
Page 53
NOTE: Password protection does not take effect until the system reboots. Using your system password to secure your system About this task If you have assigned a setup password, the system accepts your setup password as an alternate system password. Steps 1.
Page 54
● If System Password is not set to Enabled and is not locked through the Password Status option, you can assign a system password. For more information, see the System Security Settings screen section. ● You cannot disable or change an existing system password. NOTE: You can use the password status option with the setup password option to protect the system password from unauthorized changes.
Dell Lifecycle Controller Dell Lifecycle Controller (LC) provides advanced embedded systems management capabilities including system deployment, configuration, update, maintenance, and diagnosis. LC is delivered as part of the iDRAC out-of-band solution and Dell system embedded Unified Extensible Firmware Interface (UEFI) applications.
Table 60. Boot Manager details (continued) Option Description System Utilities Enables you to launch System Utilities menu such as Launch Diagnostics, BIOS update File Explorer, Reboot System. PXE boot You can use the Preboot Execution Environment (PXE) option to boot and configure the networked systems remotely. To access the PXE boot option, boot the system and then press F12 during POST instead of using standard Boot Sequence from BIOS Setup.
Minimum to POST and system management configuration validation This section describes the minimum to POST system requirement and system management configuration validation of the Dell system. Topics: • Minimum configuration to POST • Configuration validation Minimum configuration to POST The components listed below are the minimum configuration to POST: ●...
Table 61. Configuration validation error (continued) Error Description Possible cause and Example recommendations Comm Error A configuration element is not responding System management Comm Error: Backplane 2 to iDRAC using the management interface sideband communication while running an inventory check. Unplug AC Power, reseat the element and replace the element if the problem...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
2. Disconnect the system from the electrical outlet, and disconnect the peripherals. 3. If applicable, remove the system from the rack. For more information, see the Rail Installation Guide relevant to your rail solutions at www.dell.com/poweredgemanuals. 4. Remove the system cover.
For information about DC PSU cabling instructions, go to https://www.dell.com/poweredgemanuals > Rack Servers > PowerEdge R6615 > Select This Product > Documentation > Manuals and Documents > Cabling instructions for – 48 – 60 V DC power supply. Optional front bezel NOTE: LCD panel is optional on the front bezel.
Figure 23. Removing the front bezel Installing the front bezel Prerequisites 1. Follow the safety guidelines listed in the Safety Instructions. 2. Keep the bezel key handy. NOTE: The bezel key is part of the bezel package. Steps 1. Align and insert the tabs on the bezel into the slots on the chassis. 2.
Figure 24. Installing the front bezel System cover Removing the system cover Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system. 3. Power off the system, including any attached peripherals. 4.
Figure 25. Removing the system cover Next steps Replace the system cover. Installing the system cover Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system. 3. Ensure that all internal cables are connected and placed out of the way, and no tools or extra parts are left inside the system.
Figure 26. Installing the system cover Next steps Follow the procedure listed in After working inside your system. Drive backplane cover Removing the drive backplane cover Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system.
Figure 27. Removing the drive backplane cover Next steps Install the drive backplane. Installing the drive backplane cover Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system.
Page 67
Figure 28. Installing the drive backplane cover Next steps Follow the procedure listed in After working inside your system. Installing and removing system components...
Air shroud Removing the air shroud Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system. CAUTION: Never operate your system with the air shroud removed. The system may get overheated quickly, resulting in shutdown of the system and loss of data.
Figure 30. Installing the air shroud Next steps Follow the procedure listed in After working inside your system. Cooling fan Removing a cooling fan Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in Before working inside your system.
Figure 31. Removing a cooling fan Next steps Replace a cooling fan. Installing a cooling fan Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in Before working inside your system. 3. If installed, Remove the air shroud.
Figure 32. Installing a cooling fan Next steps 1. If removed, Install the air shroud. 2. Follow the procedure listed in After working inside your system. Drives Removing a drive blank Prerequisites 1. Follow the safety guidelines listed in the Safety instructions.
Next steps Replace the drive blank. Installing a drive blank Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system. Steps Slide the drive blank into the drive slot until the release button clicks into place. Figure 34.
Figure 35. Removing a drive carrier Next steps Replace the drive or a drive blank. Installing the drive carrier Prerequisites CAUTION: Before removing or installing a drive while the system is running, see the documentation for the storage controller card to ensure that the host adapter is configured correctly to support drive removal and insertion.
Figure 36. Installing a drive carrier Next steps install the front bezel. Removing the drive from the drive carrier Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. Remove the drive carrier. Steps 1. Using a Phillips #1 screwdriver, remove the screws from the slide rails on the drive carrier. NOTE: If the drive carrier has Torx screw, use Torx 6 (for 2.5-inch drive) or Torx 8 (for 3.5-inch drive) screwdriver to remove the drive.
Figure 37. Removing the drive from the drive carrier Next steps Install the drive into the drive carrier. Installing the drive into the drive carrier Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. Remove the drive blank. Steps 1.
Figure 38. Installing a drive into the drive carrier Next steps Install the drive carrier. Rear drive module Removing the rear drive module Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system.
Figure 39. Removing the rear HDD Next steps Replace the rear drive module. Installing the rear drive module Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system.
Figure 40. Installing rear drive module Next steps 1. Connect all the cables to the rear drive module. Install the rear drives. Install the air shroud. 4. Follow the procedure listed in After working inside your system Drive backplane Drive backplane Depending on your system configuration, the drive backplanes supported are listed here: Table 64.
Figure 44. Removing the drive backplane Next steps Replace the drive backplane. Installing the drive backplane Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system. Remove the backplane cover.
Figure 45. Installing the drive backplane Next steps 1. Connect the drive backplane cables to the connectors on the system board and backplane. Install the drives. 3. If removed, install the air shroud. Install the drive backplane cover. 5. Follow the procedure listed in After working inside your system.
Figure 46. Right ,left, and center brackets Removing the side wall bracket There are two side wall brackets on either side of the system. The procedure to remove is similar. Prerequisites 1. Follow the safety guidelines listed in the Safety instructions.
Figure 47. Removing the side wall bracket Next steps Replace the side wall bracket. Installing the side wall bracket There are two side wall brackets on either side of the system. The procedure to install is similar. Prerequisites 1. Follow the safety guidelines listed in the Safety instructions.
Figure 48. Installing the side wall bracket Next steps Replace the cooling fan. 2. If removed, install the air shroud. 3. If removed, install the drive backplane cover. 4. Follow the procedure listed in the After working inside your system. Cable routings Figure 49.
Page 85
NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse sequential order. Table 66. 4 x 3.5-inch SAS3/SATA RAID Order From SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector) SL1 (signal connector on system board) CTRL_DST_PA1 (front PERC) NOTE:...
Page 86
Figure 51. 8 x 2.5-inch NVMe RAID (w/ FPERC11 N) NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse sequential order. Table 68. 8 x 2.5-inch NVMe RAID (w/ FPERC11 N) Order From SIG_PWR_1 (system board power connector)
Page 87
Figure 52. 8 x 2.5-inch NVMe RAID (w/ FPERC12) NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse sequential order. Table 69. 8 x 2.5-inch NVMe RAID (w/ FPERC12) Order From SIG_PWR_1 (system board power connector)
Page 88
Figure 53. 10 x 2.5-inch SAS4/SATA RAID (w/ FPERC11) NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse sequential order. Table 70. 10 x 2.5-inch SAS4/SATA RAID (w/ FPERC11) Order From SIG_PWR_1 (system board power connector)
Page 89
NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse sequential order. Table 71. 10 x 2.5-inch SAS4/SATA RAID (w/ FPERC12) Order From SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector) SL1 (signal connector on system board) CTRL_DST_PA1 (front PERC) SL3 (signal connector on system board)
Page 90
Figure 56. 10 x 2.5-inch w/ 4x Uni G4 (w/ FPERC12) NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse sequential order. Table 73. 10 x 2.5-inch w/ 4x Uni G4 (w/ FPERC11) Order From SIG_PWR_1 (system board power connector)
Page 91
Figure 57. 10 x 2.5-inch SAS4/SATA RAID w/ Rear 2 x 2.5-inch (w/ FPERC11) NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse sequential order. Table 74. 10 x 2.5-inch SAS4/SATA RAID (w/ FPERC11) Order From SIG_PWR_1 (system board power connector)
Page 92
Figure 58. 10 x 2.5-inch SAS4/SATA RAID w/ Rear 2 x 2.5-inch (w/ FPERC12) NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse sequential order. Table 75. 10 x 2.5-inch SAS4/SATA RAID (w/ FPERC12) Order From SIG_PWR_1 (system board power connector)
Figure 59. 10 x U.2 G4 NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse sequential order. Table 76. 10 x U.2 G4 Order From SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector) SL1 (signal connector on system board) CTRL_DST_PA1 (front PERC)
2. Using a Phillips #2 screwdriver, loosen the captive screws on the front PERC module. 3. Pull the front PERC module to disengage from the connector on the drive backplane. NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence. Figure 60.
Figure 61. Installing the front mounting front PERC module Next steps 1. Reconnect the required cables. 2. If removed, replace the air shroud. Install the drive backplane cover. 4. Follow the procedure listed in After working inside your system. Removing the rear mounting front PERC module Prerequisites 1.
Figure 62. Removing the rear mounting front PERC module 3. Using a Phillips #2 screwdriver, remove the three screws securing the front PERC bracket to the drive backplane. 4. Lift the front PERC bracket away from the drive backplane. Next steps Replace the rear mounting front PERC module.
Figure 63. Installing the rear mounting front PERC module Next steps Install the drive backplane. 2. If removed, install the air shroud. Install the drive backplane cover. 4. Follow the procedure listed in After working inside your system. System memory System memory guidelines The PowerEdgeR6615 system supports DDR5 registered DIMMs (RDIMMs).
Page 98
Figure 64. Memory channels Memory channels are organized as follows: Installing and removing system components...
Table 77. Memory channels Proce Chan Chan Chann Chann Channe Chann Channel Channel Channe Channe Channe Channe ssor nel A nel B el C el D el F Proces Slot Slot Slot A3 Slot A9 Slot A7 Slot Slot A2 Slot A6 Slot A4 Slot A10...
● Minimum recommended configuration is to populate four equal memory modules per processor. Removing a memory module Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system. Remove the air shroud.
NOTE: Ensure the socket ejector latches are fully open, before installing the memory module. 3. Align the edge connector of the memory module with the alignment key of the memory module socket, and insert the memory module in the socket. CAUTION: To prevent damage to the memory module or the memory module socket during installation, do not bend or flex the memory module;...
NOTE: Follow the screw sequence defined on the heat sink label. Disassembly order: 6, 5, 4, 3, 2, 1 NOTE: The captive screw numbers are marked on the heat sink. 2. Lift the heat sink from the system. Figure 67. Removing a heat sink Next steps If you are removing a faulty heat sink, replace the heat sink, if not,remove the...
6. Using a Torx #T20 screwdriver, fully loosen the captive screw all the way before moving to the next screw (on one-screw- at-a-time basis). NOTE: Follow the screw sequence defined on the heat sink label. Disassembly order: 6, 5, 4, 3, 2, 1. NOTE: The captive screw numbers are marked on the heat sink.
Page 104
Steps 1. Using a Torx #T20 screwdriver, loosen the middle screw to release the retention frame. Hold and lift the retention frame upwards and rotate it slightly pass the vertical position(105 degrees). NOTE: The spring loading will keep the retention frame at its "open" position. Figure 69.
3. Holding the handle on the carrier frame, slide the tray out of the rail frame. Figure 71. Removing the carrier frame Next steps Replace the AMD processor. Installing the AMD processor Prerequisites 1. Follow the safety guidelines listed in the Safety instructions.
Page 106
Figure 72. Placing the carrier frame into the rail frame 2. Holding both of blue tabs to push the rail frame down until the blue latches lock into place. Figure 73. Closing the rail frame 3. Secure the retention frame by holding down the retention frame with one hand while using the other hand to operate the screw driver to engage and tighten screw.
NOTE: Press the retention frame while tightening the screws to avoid tilting of the processor cover out of the processor socket. Figure 74. Securing the retention frame Next steps Install the heat sink Install the liquid cooling module. Install the air shroud.
Page 108
Figure 75. Applying thermal grease CAUTION: Applying too much thermal grease can result in excess grease coming in contact with and contaminating the processor socket. NOTE: The thermal grease syringe is intended for single use only. Dispose of the syringe after you use it. NOTE: Refer to the airflow direction on heat sink label as visual hint of heat sink install orientation.
Figure 76. Installing the heat sink Next steps Install the air shroud. 2. Follow the procedure listed in the After working inside your system. Installing the Direct Liquid Cooling module Prerequisites Never uninstall the Direct Liquid Cooling (DLC) module from a processor unless you intend to replace the processor or system board.
A system event entry is logged in the iDRAC Lifecycle Controller if an expansion card riser is not supported or missing. It does not prevent your system from turning on. However, if a F1/F2 pause occurs with an error message, see Troubleshooting expansion cards section in the Dell EMC PowerEdge Servers Troubleshooting Guide at www.dell.com/ poweredgemanuals.
Page 115
Figure 86. Riser 4P 1. Slot 2 NOTE: The expansion-card slots are not hot-swappable. The following table provides guidelines for installing expansion cards to ensure proper cooling and mechanical fit. The expansion cards with the highest priority should be installed first using the slot priority indicated. All the other expansion cards should be installed in the card priority and slot priority order.
Page 116
Table 81. PCIe Riser Configurations (continued) Config No. of PERC Rear x8 CPU 1 x8 CPU x16 CPU x16 CPU x16 CPU x16 CPU x16 CPU uratio Config CPUs type Storage Slot1 LP 2 Slot2 1 Slot1 1 Slot2 1 Slot3 1 Slot1 1 Slot2 uratio...
Page 128
2. Follow the procedure listed in the Before working inside your system. Remove the air shroud. NOTE: If BOSS-N1 module is installed, ensure to disconnect the BOSS-N1 power cable and Signal cable before removing the Riser 1 cage. 5. If applicable, disconnect the cables from the expansion card or system board. Steps 1.
Page 129
Figure 88. Removing the expansion card riser 2 Figure 89. Removing the expansion card riser 3 Installing and removing system components...
Page 130
Figure 90. Removing the expansion card riser 4 3. If the risers are not going to be replaced, install riser blanks, and if required tighten the captive screws. NOTE: You must install a filler bracket over an empty expansion card slot to maintain Federal Communications Commission (FCC) certification of the system.
Install Riser 2 before installing Riser 1 and Riser 3. Install Riser 4 after installing Riser 3. CAUTION: Do not install GPUs, network cards, or other PCIe devices on your system that are not validated and tested by Dell. Damage caused by unauthorized and invalidated hardware installation will null and void the system warranty. Steps 1.
Page 132
Figure 93. Removing the Riser 1 blank Figure 94. Removing the Riser 2 blank 2. Holding the edges or the touch points, align the holes on the expansion card riser with the guides on the system board. 3. Lower the expansion card riser into place and press the touch points until the expansion card riser connector is fully seated on the system board connector.
Page 133
Figure 95. Installing the expansion card riser 1 Figure 96. Installing the expansion card riser 2 Installing and removing system components...
Figure 97. Installing the expansion card riser 3 Figure 98. Installing the expansion card riser 4 Next steps 1. If required, reconnect the cables to the expansion card or system board. Install the air shroud 3. Follow the procedure listed in After working inside your system.
Page 135
3. If applicable, disconnect the cables from the expansion card. Remove the air shroud. Remove the expansion card riser. Steps 1. Tilt the expansion card retention latch lock to open. 2. Pull the card holder before removing the card from the riser. 3.
For instructions, see the documentation accompanying the card. CAUTION: Do not install GPUs, network cards, or other PCIe devices on your system that are not validated and tested by Dell. Damage caused by unauthorized and invalidated hardware installation will null and void the system warranty. Steps 1.
Page 137
2. If installed, remove the filler bracket. NOTE: Store the filler bracket for future use. Filler brackets must be installed in empty expansion card slots to maintain Federal Communications Commission (FCC) certification of the system. The brackets also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system.
Figure 102. Installing an expansion card into the expansion card riser Next steps 1. If applicable, connect the cables to the expansion card. Install the expansion card risers. Install the air shroud. 4. Follow the procedure listed in After working inside your system.
Figure 103. Removing the serial COM port Next steps Replace the serial COM port. Installing the serial COM port The procedure to install serial COM port to Riser 3 or 4 is same. Prerequisites 1. Follow the safety guidelines listed in the Safety instructions.
Figure 104. Installing the serial COM port Next steps Install the air shroud. 2. Follow the procedure listed in After working inside your system. VGA module Removing the VGA module Prerequisites 1. Follow the safety guidelines listed in the Safety instructions.
3. Using Phillips #2 screwdriver, remove the screw on the VGA module. 4. Slide the VGA module out of the system. NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence. Figure 105.
Figure 106. Installing the VGA module Next steps 1. Route the VGA cable, close the cable latch, and connect the VGA cable to the connector on the system board. 2. Route and connect the right control panel cable. 3. If removed, Install the air shroud.
Figure 107. Removing the M.2 NVMe SSD module Next steps Replace the M.2 NVMe SSD module. Installing the M.2 NVMe SSD module Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system.
Next steps 1. Install the BOSS_N1 module. 2. Follow the procedure listed in the After working inside your system. Optional BOSS-N1 module Removing the BOSS-N1 module blank Prerequisites Follow the safety guidelines listed in the Safety instructions. Steps 1. Using a Phillips #1 screwdriver, remove the screw that secures the BOSS-N1 module bay to the chassis. 2.
Figure 110. Installing the BOSS-N1 module blank Removing the BOSS-N1 card carrier blank Prerequisites Follow the safety guidelines listed in the Safety instructions. Steps 1. Disconnect the power cable and the signal cable from the system board. 2. Using a Phillips #1 screwdriver, remove the screws that secures the BOSS-N1 card carrier blank to the chassis. 3.
Figure 111. Removing the BOSS-N1 card carrier blank Next steps Replace the BOSS-N1 card carrier blank install BOSS-N1 card carrier. Installing the BOSS-N1 card carrier blank Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. Steps 1. Align the blank with the BOSS-N1 module bay and push it into the bay until it clicks into place. 2.
Figure 112. Installing the BOSS-N1 card carrier blank Removing the BOSS-N1 module The procedure to remove is the BOSS-N1 module with 4 x 2.5-inch rear drive module is similar. Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2.
Page 148
Figure 113. Removing the BOSS-N1 card carrier 3. Using the Phillips #1 screwdriver remove the M3 x 0.5 x 4.5 mm screw that secures the M.2 SSD to the BOSS-N1 card carrier. 4. Slide the M.2 SSD out from the BOSS-N1 card carrier. Figure 114.
Page 149
Figure 115. Removing the BOSS-N1 module 8. Press the metal clip to remove the BOSS-N1 signal cable from the BOSS-N1 module. Figure 116. Removing the BOSS-N1 power and signal cable from the BOSS-N1 module NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence. Next steps Replace the BOSS-N1 module Install the BOSS-N1 module...
Installing the BOSS-N1 module The procedure to install is the BOSS-N1 module with 4 x 2.5-inch rear drive module is similar. Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system.
Page 151
Figure 118. Installing the BOSS-N1 module 5. Align the M.2 SSD at an angle with the BOSS-N1 card carrier. 6. Insert the M.2 SSD until it is firmly seated in the BOSS-N1 card carrier. 7. Using the Phillips #1 screwdriver, secure the M.2 SSD on the BOSS-N1 card carrier with the M3 x 0.5 x 4.5 mm screw. Figure 119.
Figure 120. Installing the BOSS-N1card carrier NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence. Next steps 1. Follow the procedure listed in the After working inside your system. System battery Replacing the system battery Prerequisites NOTE:...
Page 153
Figure 121. Removing the system battery 2. To install a system battery, press the battery into the connector until it snaps into place. 3. Insert the battery in the battery holder until the battery holder clip snaps into place. Figure 122. Installing the system battery Next steps Install the air shroud.
f. Enter the System Setup and if the time and date are still incorrect, see Getting help section. Optional internal USB card NOTE: To locate the internal USB port on the system board, see the System board jumpers and connectors section.
Installing the internal USB card Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system. Remove the expansion card risers. Steps 1. Connect the USB key to the internal USB card. NOTE: For information about the exact location of USB on system board, see System board jumpers and connectors...
Steps 1. Disconnect and remove the intrusion switch cable connector from connector on the system board. NOTE: Observe the routing of the cable as you remove it from the system. 2. Using a Phillips #2 screwdriver, remove the screw that secures the intrusion switch on the intrusion switch slot. 3.
Figure 126. Installing the intrusion switch Next steps Install the air shroud. 2. Follow the procedure listed in After working inside your system. Optional OCP card Removing the OCP card Prerequisites 1. Follow the safety guidelines listed in the Safety instructions.
CAUTION: Do not install GPUs, network cards, or other PCIe devices on your system that are not validated and tested by Dell. Damage caused by unauthorized and invalidated hardware installation will null and void the system warranty. Steps 1. If installed, remove the filler bracket.
Figure 128. Installing the OCP card Next steps Install the expansion card riser. 2. Follow the procedure listed in After working inside your system. Control panel This is a service technician replaceable part only. Removing the right control panel Prerequisites 1.
Figure 129. Removing the right control panel Next steps Replace the right control panel. Installing the right control panel Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system.
Figure 130. Installing the right control panel Next steps Install the side wall bracket. Install the cooling fan. Install the drive backplane cover. 4. If removed, install the air shroud. 5. Follow the procedure listed in After working inside your system.
Figure 131. Removing the left control panel Next steps Replace the left control panel. Installing the left control panel Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system.
● If the load on the active PSU falls below 20 percent of PSU rated power wattage, then the redundant PSU is switched to the sleep state. You can configure the hot spare feature by using the iDRAC settings. For more information, see the iDRAC User’s Guide available at www.dell.com/poweredgemanuals. Installing and removing system components...
Removing a power supply unit blank Prerequisites Follow the safety guidelines listed in the Safety instructions. Steps Pull the blank out of the system. CAUTION: To ensure proper system cooling, the PSU blank must be installed in the second PSU bay in a non-redundant configuration.
NOTE: For information about the cable management when the PSU is removed or installed while the system is in a rack, see the system’s cable management arm documentation at https://www.dell.com/poweredgemanuals. Steps Press the release latch and holding the PSU handle, slide the PSU out of the bay.
PSU is removed or installed while the system is in the rack, see the system’s cable management accessory documentation at https://www.dell.com/poweredgemanuals. 2. Connect the power cable to the PSU, and plug the cable into a power outlet.
Steps 1. Locate the TPM connector on the system board. For more information, see system board connectors. 2. Press to hold the module down and remove the screw using the security Torx 8-bit shipped with the TPM module. 3. Slide the TPM module out from its connector. 4.
Initializing the TPM 2.0 for users Steps 1. While booting your system, press F2 to enter System Setup. 2. On the System Setup Main Menu screen, click System BIOS > System Security Settings. 3. From the TPM Security option, select On. 4.
Figure 138. Removing the system board Next steps Install the system board. Installing the system board Prerequisites NOTE: Before replacing the system board, replace the old iDRAC MAC address label in the Information tag with the iDRAC MAC address label of the replacement system board. 1.
Page 170
4. If you are not using Easy Restore, import your new or existing iDRAC Enterprise license. For more information, see the Integrated Dell Remote Access Controller User's Guide available at https://www.dell.com/idracmanuals. 5. Follow the procedure listed in After working inside your system.
Restoring Service Tag using Easy Restore The Easy Restore feature allows you to restore your Service Tag, iDRAC license, UEFI configuration, and the system configuration data after replacing the system board. All data is backed up in a backup Flash drive device automatically. If BIOS detects a new system board, and the Service Tag in the backup Flash drive device is different, BIOS prompts the user to restore the backup information.
Page 172
Steps 1. Using a Phillips # 2 screwdriver, remove the screws that secure the LAN on Motherboard (LOM) card and rear I/O board to the system board. 2. Holding the edges, pull the LOM card or rear I/O board to disconnect from the connector on the system board. Figure 140.
Installing the LOM card and rear I/O board Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system. Remove the system board. NOTE: The procedure to install the liquid cooling rear I/O board and rear I/O boards is same. Steps 1.
Page 174
Figure 143. Installing the LOM card and Liquid cooling rear I/O board Next steps Install the system board. 2. Follow the procedure listed in After working inside your system. Installing and removing system components...
Upgrade Kits The table lists the available After Point Of Sale [APOS] kits. Table 91. Upgrade kits Kits Related links to service instructions Bezel Installing the front bezel M.2 SSD Installing the M.2 SSD module BOSS-N1 Installing the BOSS-N1 controller card module Drives Installing the drive Memory...
Page 176
Before you begin the installation or removal process, follow the Safety instructions Before working inside your system instructions. Table 92. BOSS-N1 module kit components R660 (quantity) Components in kit BOSS cover M3 x 0.05 x 4.5 mm screws BOSS signal cable BOSS power cable BOSS-N1 module 1 or 2...
Figure 145. Installing the BOSS-N1 module blank To install the BOSS-N1 module: 1. Install the BOSS-N1 module . To install the BOSS-N1 , see installing the BOSS-N1 module. 2. Install the M.2 SSD. To install the M.2 SSD, see installing M.2 SSD.
Page 178
Figure 146. Front View of the DPU card Figure 147. Rear view of the DPU card NOTE: Mellanox Bluefield2 25Gbe card supports only Nvidia Channel FW and Channel Driver, and does not support Dell FW/Driver SWB DUP updates. Upgrade Kits...
Serial COM port kit The serial COM port kit contains the components that are listed in the table. Table 93. Serial COM port kit Components Quantity Serial COM port card Cable For installation procedure of the serial COM port, see serial COM port section.
VGA port kit The VGA port kit contains the components listed in the table. Table 94. VGA port kit Components Quantity VGA port card Cable For installation procedure of the VGA port, see VGA port section. VGA port kit...
Internal USB card kit The internal USB card kit contains one internal USB card. For installation of internal USB card, see internal USB card section. Internal USB card kit...
Jumpers and connectors This section provides essential and specific information about jumpers and switches. It also describes the connectors on the various boards in the system. Jumpers on the system board help to disable the system and reset the passwords. To install components and cables correctly, you must be able to identify the connectors on the system board.
Page 183
Table 95. System board jumpers and connectors (continued) Item Connector Description Battery SIG connector Battery SIG connector Rear I/O connector Rear I/O connector (SL9_CPU_PB5) PCIe connector 9 Coin Cell battery Coin Cell battery A1, A5, A3, A9, A7, and A11 DIMMs for CPU for Channels A, B, C, D, E, and OCP NIC 3.0 connector OCP NIC 3.0 connector...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
System diagnostics and indicator codes The diagnostic indicators on the system front panel display system status during system startup. Topics: • Power button LED • Status LED indicators • System health and system ID indicator codes • iDRAC Quick Sync 2 indicator codes •...
Page 186
Figure 150. Status LED indicators Table 98. Status LED indicators and descriptions Icon Description Condition Corrective action ● Check the System Event Log to determine if the drive has an error. ● Run the appropriate Online Diagnostics test. The indicator turns solid amber if Restart system embedded...
Table 98. Status LED indicators and descriptions (continued) Icon Description Condition Corrective action If the problem persists, see the Getting help section. NOTE: For more information about the supported PCIe cards, see the Expansion cards and expansion card risers > Expansion card installation guidelines section.
If the problem persists, see the Getting help section. www.dell.com/poweredgemanuals Dell OpenManage Server Administrator User’s Guide at https://www.dell.com/ openmanagemanuals. Solid amber Indicates that the system is in fail-safe Restart the system. If the problem mode.
The LCD panel is used to configure or view the iDRAC IP address of the system. For information about the event and error messages generated by the system firmware and agents that monitor system components, go to qrl.dell.com >...
For information about the event and error messages generated by the system firmware and agents that monitor system components, go to qrl.dell.com > Look Up > Error Code, type the error code, and then click Look it up..
NIC indicator codes Each NIC on the back of the system has indicators that provide information about the activity and link status. The activity LED indicator indicates if data is flowing through the NIC, and the link LED indicator indicates the speed of the connected network. Figure 153.
Page 192
Table 106. AC and DC PSU status indicator codes Power indicator codes Condition Green Indicates that a valid power source is connected to the PSU and the PSU is operational. Blinking amber Indicates an issue with the PSU. Not powered on Indicates that the power is not connected to the PSU.
Using system diagnostics If you experience an issue with the system, run the system diagnostics before contacting Dell for technical assistance. The purpose of running system diagnostics is to test the system hardware without using additional equipment or risking data loss.
Dell Embedded System Diagnostics NOTE: The Dell Embedded System Diagnostics is also known as Enhanced Pre-boot System Assessment (ePSA) diagnostics. The Embedded System Diagnostics provide a set of options for particular device groups or devices allowing you to: ● Run tests automatically or in an interactive mode ●...
Dell contact information on your purchase invoice, packing slip, bill or Dell product catalog. The availability of services varies depending on the country and product, and some services may not be available in your area. To contact Dell for sales, technical...
You can use the Quick Resource Locator (QRL) located on the information tag in the front of the system, to access information about PowerEdge R6615. There is also another QRL for accessing product information located on the back of the system cover.
Dell. This information is used by Dell Technical Support to troubleshoot the issue. ● Proactive contact — A Dell Technical Support agent contacts you about the support case and helps you resolve the issue. The available benefits vary depending on the Dell Service entitlement purchased for your device. For more information about SupportAssist, go to www.dell.com/supportassist.
This section provides information about the documentation resources for your system. To view the document that is listed in the documentation resources table: ● From the Dell support site: 1. Click the documentation link that is provided in the Location column in the table.
Page 199
Methods to download firmware and drivers section in this document. Managing your system For information about systems management www.dell.com/poweredgemanuals software offered by Dell, see the Dell OpenManage Systems Management Overview Guide. For information about setting up, using, www.dell.com/openmanagemanuals >...