APPLICATION

The HE420A,B and HE460A,B Steam Power Humidifiers use
a thermal fan interlock control to provide humidification for
the whole house. The steam power humidifier is designed to
work with high efficiency furnaces, heat pumps and set back
thermostats. The humidifiers work with virtually any
Honeywell humidity control, but use the Honeywell Perfect
Climate Comfort Center™ control for optimal performance.
Incloy® is a Registered Trademark of Chromalox® Wiegand, division of Emerson Electric Co.
Copyright © 1998 Honeywell Inc. • All Rights Reserved
HE420A,B and HE460A,B
Steam Power Humidifiers

FEATURES

• Humidifies the air without a call for heat from the
thermostat so relative humidity fluctuates less,
optimizing homeowner comfort.
• Ideal for homes with extensive woodwork, hardwood
floors, antiques, oil paintings, leather furniture,
pianos, and fine collectibles.
• Capable of humidifying a large area.
• Compact size allows easy installation.
• Minimal amount of water needed for energy efficient
operation.
• Low water cut-off switch and built-in overflow
protection are integral safety features.
• Automatic Flushing Timer reduces frequency of
maintenance in a hard water installation.
• Includes easy-to-use humidity control that mounts
on the wall or duct for more installation flexibility.
• Perfect Climate Comfort Center™ control can be
installed to replace both the thermostat and
humidity control for improved aesthetics and
convenience.
Application .......................................................................... 1
Features .............................................................................. 1
Specifications ...................................................................... 2
Ordering Information ........................................................... 2
Installation ........................................................................... 3
Wiring .................................................................................. 5
Plumbing Humidifier ........................................................... 6
Set Water Level .................................................................. 6
Finish Mounting and Plumbing Humidifier ......................... 7
Installing HC40 Automatic Flushing Timer ......................... 7
Checking the Installation .................................................... 8
Operating the Humidifier .................................................... 8
Operation ............................................................................ 9
Maintenance ....................................................................... 9
Checkout Procedures ......................................................... 10
Troubleshooting .................................................................. 10
Replacement parts ............................................................. 11
PRODUCT DATA
Contents
68-0192-2

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell HE420A

  • Page 1: Table Of Contents

    The HE420A,B and HE460A,B Steam Power Humidifiers use a thermal fan interlock control to provide humidification for the whole house. The steam power humidifier is designed to work with high efficiency furnaces, heat pumps and set back thermostats.
  • Page 2: Specifications

    Honeywell Inc., 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 (612) 951-1000 In Canada—Honeywell Limited/Honeywell Limitée, 155 Gordon Baker Road, North York, Ontario M2H 3N7. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
  • Page 3: Installation

    HE420A,B AND HE460A,B STEAM POWER HUMIDIFIERS INSTALLATION IMPORTANT Read all the installation instructions before installing the humidifier. M ID M ID Select Location and Mount There are three typical ways of mounting the steam humidifier: • horizontally under at least a 10 in. (254 mm) wide duct using the mounting bracket (preferred mounting);...
  • Page 4 HE420A,B AND HE460A,B STEAM POWER HUMIDIFIERS WARNING Electrocution, Heavy Equipment and Chemical Hazard. Can cause death, blindness, water damage to home and heater failure. 1/2 IN. (13 MM) • Do not cut into any air conditioning or electrical FROM EDGE line.
  • Page 5: Wiring

    HE420A,B AND HE460A,B STEAM POWER HUMIDIFIERS Mount Horizontally on Reinforced Duct Air Mover Applications This horizontal mounting method usually requires duct reinforcement to support the weight of the humidifier and CAUTION keep it level. See Fig. 3. The mounting bracket is not used.
  • Page 6: Plumbing Humidifier

    120°F (49°C). IMPORTANT Adjust the humidifier water level prior to mounting. The Honeywell S688A Fan Sail Switch must be 1. Set the humidifier reservoir on a level surface. installed if the system fan is on continuously.
  • Page 7: Finish Mounting And Plumbing Humidifier

    HE420A,B AND HE460A,B STEAM POWER HUMIDIFIERS FINISH MOUNTING AND STEAM HUMIDIFIER PLUMBING HUMIDIFIER HC40 AUTOMATIC 1. Mount humidifier as instructed in the Select Location FLUSHING and Mount section. TIMER DRAIN 2. Route the tubing to the humidifier float valve .
  • Page 8: Checking The Installation

    HE420A,B AND HE460A,B STEAM POWER HUMIDIFIERS temperature setting scale on your humidity control. Match SLOT FOR COIN the dial setting to the outdoor temperature to optimize the humidity level while reducing the moisture condensation on your windows. Use Table 2 to adjust the humidity control to the recommended setting.
  • Page 9: Operation

    Decrease the frost factor dial by windows one setting. OPERATION The HE420A,B and HE460A,B Humidifiers use the principle FLOAT that hot water creates water vapor. As dry air and vapor mix, VALVE ARM the relative humidity of the air rises. The humidity control...
  • Page 10: Checkout Procedures

    HE420A,B AND HE460A,B STEAM POWER HUMIDIFIERS IMPORTANT IMPORTANT • Replace the float valve when it shows any signs of Be sure the humidifier power is off and there is no deterioration. water in the humidifier. • The float valve should shut off the water at 2-3/8 in.
  • Page 11: Replacement Parts

    HE420A,B AND HE460A,B STEAM POWER HUMIDIFIERS REPLACEMENT PARTS Refer to Fig. 14 and Table 5 when ordering replacement parts. M12238B Fig. 14. Exploded view of humidifier parts. Table 5. List of Replacement Parts for HE420A,B, HE460A,B Humidifiers. Exploded View HE420 Part HE460 Part Number...
  • Page 12 Home and Building Control Home and Building Control Honeywell Asia Pacific Inc. Honeywell Inc. Honeywell Limited-Honeywell Limitée Room 3213-3225 Honeywell Plaza 155 Gordon Baker Road Sun Hung Kai Centre P.O. Box 524 North York, Ontario No. 30 Harbour Road Minneapolis MN 55408-0524...