6.2.4

Rebuilding failed drives

You can manually rebuild failed hard disk drives using the Rebuild command in the
Management Menu.
To rebuild a failed hard disk drive
From the Management Menu, select Rebuild, and then press <Enter>.
1.
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
The PHYSICAL DRIVES SELECTION MENU displays the available drives
2.
connected to the SATA ports. Select the drive you want to rebuild, and then
press <Space>.
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Virtual Drives
6-16
LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010
BIOS Version
LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010
BIOS Version
REBUILD - PHYSICAL DRIVES SELECTION MENU
0
1
Port # 1 DISK
77247MB
A.10.09231523R
Rebuild PD(s)
A.10.09231523R
PORT #
ONLIN A00-00
FAIL A00-01
HDS728080PLA380
PF20A60A