Page 1
Documentation CD. You can also find the most current information about your ServerGuide to Go to the Web for instructions, server on the IBM Web site at: install operating http://www.ibm.com/pc/support http://www.ibm.com/pc/support system? Install applications, such as IBM systems...
Page 2
Check all cables for loose connections and verify that all optional devices you installed are on the ServerProven list. You can view the ServerProven list at http://www.ibm.com/pc/compat/ View information about IBM support line at http://www.ibm.com/services/sl/products/ or view support telephone numbers at Problem http://www.ibm.com/planetwide/...
Page 3
IBM xSeries 260 Type 8865 Installation Guide...
Page 8
All caution and danger statements in this documentation begin with a number. This number is used to cross reference an English caution or danger statement with translated versions of the caution or danger statement in the IBM Safety Information book.
Page 9
Statement 1: DANGER Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. v Connect all power cords to a properly wired and grounded electrical outlet.
Page 10
Statement 2: CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer.
Page 11
Statement 4: ≥ 18 kg (39.7 lb) ≥ 32 kg (70.5 lb) ≥ 55 kg (121.2 lb) CAUTION: Use safe practices when lifting. Statement 5: CAUTION: The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device.
Page 12
There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician. Statement 10: CAUTION: Do not place any object on top of rack-mounted devices. IBM xSeries 260 Type 8865: Installation Guide...
® xSeries 260 Type 8865 server and basic instructions for installing some options. More detailed instructions for installing options are in the User’s Guide on the IBM xSeries Documentation CD, which comes with the server. This document contains information about:...
Web site at http://www.ibm.com/pc/compat/. The IBM xSeries Documentation CD The IBM xSeries Documentation CD contains documentation for the server in Portable Document Format (PDF) and includes the IBM Documentation Browser to help you find information quickly. Hardware and software requirements...
Notices and statements in this document The caution and danger statements that appear in this document are also in the multilingual Safety Information document, which is on the IBM xSeries Documentation CD. Each statement is numbered for reference to the corresponding statement in the Safety Information document.
Standard: Two 775 watt 110 V or 220 V – Server on: 8% to 80% ac input dual-rated power supplies – Server off: 8% to 80% v Upgradeable to four power supplies IBM xSeries 260 Type 8865: Installation Guide...
Major components of the server Blue on a component indicates touch points, where you can grip the component to remove it from or install it in the server, open or close a latch, and so on. Orange on a component or an orange label on or near a component indicates that the component can be hot-swapped, which means that if the server and operating system support hot-swap capability, you can remove or install the component while the server is running.
Page 18
IBM xSeries 260 Type 8865: Installation Guide...
Chapter 2. Installing options This chapter provides basic instructions for installing hardware options in the server. These instructions are intended for users who are experienced with setting up IBM server hardware. If you need more detailed instructions, see the User’s Guide on the IBM xSeries Documentation CD.
To reduce the possibility of damage from electrostatic discharge, observe the following precautions: v Limit your movement. Movement can cause static electricity to build up around you. IBM xSeries 260 Type 8865: Installation Guide...
v The use of a grounding system is recommended. For example, wear an electrostatic-discharge wrist strap, if one is available. Always use an electrostatic-discharge wrist strap or other grounding system when working inside the server with the power on. v Handle the device carefully, holding it by its edges or its frame. v Do not touch solder joints, pins, or exposed circuitry.
Removing the bezel On a tower model, make sure that you unlock or remove the front cover before you remove the top cover and bezel. To remove the bezel, complete the following steps: IBM xSeries 260 Type 8865: Installation Guide...
Bezel 1. Press on the two release latches at the top edge of the bezel, and pull the top of the bezel slightly away from the server. 2. Lift the bezel to release the two tabs at the bottom edge of the bezel. 3.
You can configure your server to use memory mirroring and memory scrubbing. For detailed information about configuring your server and using these features, see the User’s Guide on the IBM xSeries Documentation CD. v To use the hot-add and hot-swap memory features, you must reconfigure your server using the Configuration/Setup Utility program.
Install the DIMMs on each memory card in the order shown in the following table. Each memory card must have at least one pair of DIMMs. See the User’s Guide on the IBM xSeries Documentation CD for additional memory configuration installation sequences.
Page 26
7. Touch the static-protective package that contains the DIMM to any unpainted metal surface on the server. Then, remove the DIMM from the package. 8. Turn the DIMM so that the DIMM keys align correctly with the slot. IBM xSeries 260 Type 8865: Installation Guide...
DIMM Retaining clip 9. Insert the DIMM into the connector by aligning the edges of the DIMM with the slots at the ends of the DIMM connector. Firmly press the DIMM straight down into the connector by applying pressure on both ends of the DIMM simultaneously.
For details about handling these devices, see “Handling static-sensitive devices” on page 8. 3. Remove the front cover (tower model only), bezel, and the top cover (see “Removing the front cover, top cover, and bezel” on page 9). IBM xSeries 260 Type 8865: Installation Guide...
Page 29
4. Remove all fans from the server. 5. Remove all memory cards from the server. 6. Remove the bezel (see “Removing the bezel” on page 10). 7. Remove the microprocessor tray: a. Open the microprocessor-tray release latch. Microprocessor-tray release latch Air baffle Microprocessor-tray lever...
Page 30
Press down on one side of the heat-sink retention clip to release it from the side of the socket; then, repeat the process on the opposite side. b. Rotate the heat-sink retention clip forward to its fully open position. IBM xSeries 260 Type 8865: Installation Guide...
Page 31
11. Remove the protective cover, tape, or label from the surface of the microprocessor socket, if any is present. 12. Lift the microprocessor-release lever to the fully-open position (approximately 135° angle). Lever fully open Lever closed 13. Touch the static-protective package that contains the new microprocessor to any unpainted metal surface on the server;...
The following sections describe how to install adapters in the server. Installing the Remote Supervisor Adapter II SlimLine An optional IBM Remote Supervisor Adapter II SlimLine can be installed only in its dedicated connector on the I/O board. The following illustration shows how to install a Remote Supervisor Adapter II SlimLine.
The ServeRAID-8i adapter is not cabled to the server, and no rerouting of the SAS cables is required. The following illustration shows how to install a ServeRAID-8i adapter. ServeRAID-8i adapter ServeRAID-8i slot For more detailed instructions or information, see the User’s Guide on the IBM xSeries Documentation CD. Chapter 2. Installing options...
For details, see the documentation that comes with the adapter. For more detailed instructions and information about installing PCI/PCI-X adapters, see the section about installing options in the User’s Guide on the IBM xSeries Documentation CD. 1. Read the safety information that begins on page v and “Installation guidelines”...
5. Install the adapter: a. Open the blue adapter guide by lifting the front edge. b. Push the orange adapter retention latch toward the rear of the server and open the tab. The power LED for the slot turns off if an adapter is installed in the slot.
Page 36
1. Insert the two tabs on the bottom of the bezel into the matching holes on the server chassis. 2. Push the top of the bezel toward the server until the locking tabs at the top of the bezel snap into place. IBM xSeries 260 Type 8865: Installation Guide...
Installing the front cover To install the front cover (tower model), complete the following steps. Unlock Lock 1. Insert the two tabs on the bottom of the front cover into the matching holes on the bezel. 2. Push the top of the front cover toward the server until the two release latches at the top of the bezel snap into place.
(SMP) server. You might have to upgrade the operating system to support SMP. For more information, see the section about using the ServerGuide Setup and Installation CD in the User’s Guide on the IBM xSeries Documentation CD and the operating-system documentation.
Page 40
CD drive activity LED: When this LED is lit, it indicates that the CD drive is in use. CD-eject button: Press this button to release a CD or DVD from the DVD drive. IBM xSeries 260 Type 8865: Installation Guide...
Rear view The following illustration shows the connectors and LEDs on the rear of the server. SP Ethernet 10/100 activity LED SP Ethernet SP Ethernet 10/100 10/100 link LED USB 2 USB 1 System serial Power-supply Video SP serial AC power DC power Fan error Gigabit Ethernet 1...
Page 42
When this LED is lit, it indicates that there is a problem with the IBM Remote Supervisor Adapter II SlimLine. IXA RS485 connector: Use this connector to connect to an iSeries server when an Integrated xSeries Adapter (IXA) is installed.
Server power features When the server is connected to an ac power source but is not turned on, the operating system does not run, and all core logic except for the service processor is shut down; however, the server can respond to requests from the service processor, such as a remote request to turn on the server.
Page 44
If the Wake on LAN feature turned on the server, the Wake on LAN feature can turn off the server. v You can turn off the server through a request from the service processor. IBM xSeries 260 Type 8865: Installation Guide...
Chapter 4. Configuring the server The ServerGuide Setup and Installation CD provides software setup tools and installation tools that are specifically designed for your IBM server. Use this CD during the initial installation of the server to configure basic hardware features and to simplify the operating-system installation.
Any standard Telnet client application can access the SOL connection. See the User’s Guide on the IBM xSeries Documentation CD for details. Using the baseboard management controller utility programs Use the baseboard management controller utility programs to configure the baseboard management controller, download firmware updates and SDR/FRU updates, and remotely manage a network.
ServeRAID controller. For information about these programs, see the documentation that comes with the ServeRAID controller and the User’s Guide on the IBM xSeries Documentation CD. If your server comes with an operating system installed, such as Microsoft Windows 2000 Datacenter Server, see the software documentation that comes with the server for configuration information.
Page 48
– Crossover cable from the SP connector to a computer. – An Ethernet cable that is connected to an Ethernet network. See the User’s Guide on the IBM xSeries Documentation CD for instructions. IBM xSeries 260 Type 8865: Installation Guide...
If you cannot locate and correct the problem using the information in this chapter, see “Getting help and technical assistance,” on page 59, the Problem Determination and Service Guide on the IBM xSeries Documentation CD, and the “Server Support” flowchart in the front of this document.
The following table provides an abbreviated list of the error codes and messages that might appear during POST. See the Problem Determination and Service Guide on the IBM xSeries Documentation CD for more information about the POST error codes and messages. See http://www.ibm.com/pc/support/ to check for updated technical information.
Page 51
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by “(Trained service technician only),”...
Troubleshooting tables The following tables list problem symptoms and suggested solutions. See the Problem Determination and Service Guide on the IBM xSeries Documentation CD for more detailed troubleshooting information. If you cannot find the problem in these charts, run the diagnostic programs. If you have run the diagnostic programs, or if running the tests does not diagnose the problem, call for service.
Page 53
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by “(Trained service technician only),”...
Page 54
4. Reseat the following components: a. Mouse or pointing device b. I/O board 5. Replace the components listed in step 4 one at a time, in the order shown, restarting the server each time. IBM xSeries 260 Type 8865: Installation Guide...
Page 55
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by “(Trained service technician only),”...
Page 56
Remote Supervisor Adapter II SlimLine (if one is present) b. I/O board 5. Replace the components listed in step 4 one at a time, in the order shown, restarting the server each time. IBM xSeries 260 Type 8865: Installation Guide...
Page 57
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by “(Trained service technician only),”...
Page 58
To prevent diskette drive read/write errors, make sure that the distance between the monitor and any external diskette drive is at least 76 mm (3 in.). b. Non-IBM monitor cables might cause unpredictable problems. 2. Reseat the following components: a. Monitor b.
Page 59
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician. An IBM optional device that 1. Make sure that all of the hardware and cable connections for the device are used to work does not work secure.
Page 60
6. If you just installed an optional device, remove it, and restart the server. If the server now turns on, you might have installed more devices than the power supply supports. IBM xSeries 260 Type 8865: Installation Guide...
Page 61
The serial-port adapter (if one is present) is seated correctly. 2. Reseat the serial port adapter. 3. Replace the serial port adapter. For more information about the serial port, see the User’s Guide on the IBM xSeries Documentation CD. A serial device does not work.
Light path diagnostics is a system of LEDs on various external and internal components of the server. When an error occurs, LEDs are lit throughout the server. By viewing the LEDs in a particular order, you can often identify the source of the error. IBM xSeries 260 Type 8865: Installation Guide...
Page 63
The server is designed so that LEDs remain lit when the server is connected to an ac power source but is not turned on, provided that the power supply is operating correctly. This feature helps you to isolate the problem when the operating system is shut down.
Page 64
3. To view the light path diagnostics panel, press the release latch on the front of the operator information panel to the left; then, slide it forward. This reveals the light path diagnostics panel. Lit LEDs on this panel indicate the type of error that has occurred. IBM xSeries 260 Type 8865: Installation Guide...
Light Path Diagnostics OVER SPEC LINK REMIND DASD RAID NONRED TEMP Look at the system service label on the top of the server, which gives an overview of internal components that correspond to the LEDs on the light path diagnostics panel. This information and the information in “Light path diagnostics panel”...
Page 66
Failing power supply or power supply filler b. (Trained service technician only) Microprocessor tray 5. If a 12 V fault has occurred, remove ac power before restoring dc power. LINK Reserved for future use IBM xSeries 260 Type 8865: Installation Guide...
Page 67
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by “(Trained service technician only),”...
Page 68
There is a fault in the Remote 1. Reseat the Remote Supervisor Adapter II SlimLine. Supervisor Adapter II SlimLine. 2. Update the firmware for the Remote Supervisor Adapter II SlimLine. 3. Replace the Remote Supervisor Adapter II SlimLine. IBM xSeries 260 Type 8865: Installation Guide...
Page 69
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by “(Trained service technician only),”...
Page 70
1. (Trained service technician only) Reseat the microprocessor tray. 2. Run diagnostic program 3. (Trained service technician only) Replace the microprocessor tray. I/O BRD The I/O board has failed. 1. Reseat the I/O board. 2. Replace the I/O board. IBM xSeries 260 Type 8865: Installation Guide...
If you need help, service, or technical assistance or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. This appendix contains information about where to go for additional...
Getting help and information from the World Wide Web On the World Wide Web, the IBM Web site has up-to-date information about IBM Eserver and IntelliStation products, services, and support. The address for IBM xSeries and BladeCenter information is http://www.ibm.com/eserver/xseries/. The address for IBM IntelliStation information is http://www.ibm.com/pc/us/intellistation/.
Web sites. The materials at those Web sites are not part of the materials for this IBM product, and use of those Web sites is at your own risk. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
Other company, product, or service names may be trademarks or service marks of others. Important notes Processor speeds indicate the internal clock speed of the microprocessor; other factors also affect application performance. IBM xSeries 260 Type 8865: Installation Guide...
IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM. Some software may differ from its retail version (if available), and may not include user manuals or all program functionality.
In the United States, IBM has established a return process for reuse, recycling, or proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal hydride, and battery packs from IBM equipment. For information on proper disposal of these batteries, contact IBM at 1-800-426-4333.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a nonrecommended modification of the product, including the fitting of non-IBM option cards. This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 22/European Standard EN 55022.
Power cords For your safety, IBM provides a power cord with a grounded attachment plug to use with this IBM product. To avoid electrical shock, always use the power cord and plug with a properly grounded outlet. IBM power cords used in the United States and Canada are listed by Underwriter’s Laboratories (UL) and certified by the Canadian Standards Association (CSA).
Page 80
Colombia, Costa Rica, Cuba, Dominican Republic, Ecuador, El Salvador, Guam, Guatemala, Haiti, Honduras, Jamaica, Mexico, Micronesia (Federal States of), Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, Saudi Arabia, Thailand, Taiwan, United States of America, Venezuela IBM xSeries 260 Type 8865: Installation Guide...
Page 82
FCC, Class A 65 software problems 50 notices and statements 3 solving problems 37 specifications 4 Standby mode 31 statements and notices 3 online publications 1 system-error LED 28 operator information panel 27 IBM xSeries 260 Type 8865: Installation Guide...
Page 83
temperature 4 top cover installing 23 removing 10 trademarks 62 troubleshooting chart 40 turning off the server 31 turning on the server 31 UI 35 United States electronic emission Class A notice 65 United States FCC Class A notice 65 Universal Serial Bus (USB) problems 50 updating the firmware code 34 USB connector 27, 29...
Page 84
IBM xSeries 260 Type 8865: Installation Guide...
Page 86
Part Number: 31R1051 Printed in USA (1P) P/N: 31R1051...