Table 11. B200xxxx Logical partition SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
5137
A problem occurred during the
startup of a partition. There was an
error writing the partition main
storage dump to the partition load
source. The main store dump startup
will continue.
5145
A problem occurred during the
startup of a partition. There was an
error writing the partition main
storage dump to the partition load
source. The main store dump startup
will continue.
5148
A problem occurred during the
startup of a partition. An error
occurred while doing a main storage
dump that would have caused
another main storage dump. The
startup will not continue.
5149
A problem occurred during the
startup of a partition while doing a
Firmware Assisted Dump that would
have caused another Firmware
Assisted Dump.
514A
A Firmware Assisted Dump did not
complete due to a copy error.
542A
A Firmware Assisted Dump did not
complete due to a read error.
542B
A Firmware Assisted Dump did not
complete due to a copy error.
543A
A Firmware Assisted Dump did not
complete due to a copy error.
543B
A Firmware Assisted Dump did not
complete due to a copy error.
543C
Informational system log entry only.
543D
A Firmware Assisted Dump did not
complete due to a copy error.
6006
During the startup of a partition, a
system firmware error occurred
when the partition memory was
being initialized; the startup will not
continue.
600A
A problem occurred during the
startup of a partition. The partition
could not reserve the memory
required for IPL.
Action
Look for other errors and resolve them.
Look for other errors and resolve them.
Go to "Isolating firmware problems" on page 222.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
No corrective action is required.
Check for server firmware updates; then, install the
updates if available.
Go to "Isolating firmware problems" on page 222.
Contact IBM support, as described in Appendix A,
"Getting help and technical assistance," on page 281.
35