Item
Analog output
D/A conversion enable/disable
control part
setting CH0, D/A conversion
setting
enable/disable setting CH1
DAC range setting CH0, DAC range
setting CH1
DAC offset value CH0, DAC offset
value CH1
Select D/A conversion value
Select D/A conversion timing
Select DAC LDAC signal
Logging part
Logging operation mode setting
setting
Buffer operation setting
Select logging start control
Select sampling pulses
Logging data size setting
Set number of sampling after
trigger
User circuit part
Logging data time division setting
setting
USER switch function enable/
disable
User circuit part parameter setting
*1 This can be set when "Logging function enable/disable" in "Logging setting" of "Module Parameter" is set to "Enable". When set to
"Disable", it is masked and cannot be set.
*2 The input filter upper limit values X8 to XF are masked and cannot be set.
*3 Output signal selection Y8 to YF are masked and cannot be set.
*4 This can be set when "External reset ON/OFF" is set to "OFF". "ON" is masked and cannot be set.
*5 This can be set when "External reset ON/OFF" is set to "OFF" and "Select output signal or I/O direction signal" is set to "User circuit
output". Otherwise it is masked and cannot be set.
*6 When "Select output signal or I/O direction signal" is set to "User circuit output", it is masked and cannot be set.
*7 Can be set when "Logging operation mode setting" is set to "Trigger operation mode". When set to "Storage operation mode", it is
masked and cannot be set.
8 FPGA MODULE CONFIGURATION TOOL
102
8.6 Parameter Setting Function
Description
Cannot be set.
Cannot be set.
Cannot be set.
Cannot be set.
Cannot be set.
Cannot be set.
*1
Select the logging operation mode.
*1
Select linear buffer operation or ring buffer
operation.
*1
Select the logging start signal.
*1
Select the logging cycle.
*1
Logging data size setting
Sets the number of times logging occurs after
*7
trigger input.
*1
Sets Non-Time division mode and Time division
mode.
Enables or disables function setting switches 7 to
10.
Page 112 User circuit part parameter setting
Setting range
Default
• Storage operation
Storage operation
mode
mode
• Trigger operation
mode
• Linear buffer operation
Linear buffer
• Ring buffer operation
operation
• User circuit output
User circuit output
• Register setting value
(RY3)
• Logging cycle timing
Logging cycle
• User circuit output
timing
• 256 records
4096 records
• 512 records
• 1024 records
• 2048 records
• 4096 records
• 8192 records
• 16384 records
• 32768 records
• 65536 records
• 131072 records
• 262144 records
• 524288 records
1 to (number of records
1
in logging data size
setting -1)
• Non-Time division
Non-Time division
mode
mode
• Time division mode
• Disable
Disable
• Enable