Set the values of the user circuit part parameters in the "User circuit part parameter setting" window.
[Menu]  [FPGA parameter]  [User circuit part parameter setting]  <Detailed settings>
12.
Write the set parameters.
[Online]  [Parameter write (Memory + Non-volatile memory)]
13.
Click the [Yes] button.
14.
Click the [Yes] button.
Implementation method and check method
Operating procedure
1.
After writing the parameters, turn the power off and on to restart the module.
2.
Start logging.
3.
Input pulses from the encoder.
4.
After 256 records of data have been collected, FTP transfer will start.
5.
Check the file transferred over FTP.
13 SAMPLE CIRCUIT IN STANDALONE MODE
13.5 When Using the Logging Function
13
389