Grounding the Switch
Figure 5: Sliding the Chassis onto the Bottom-Support Rails
1
2
3
Step 2
Use a customer-supplied rack-mount screw (an M6 x 10 mm screw or other appropriate screw for the rack) to attach each
of the two mounting brackets on the chassis to the rack and tighten each screw to the appropriate torque setting for the
screw (for M6 x 10 mm screws, use 40 in-lb [4.5 N·m] of torque).
Grounding the Switch
The switch is grounded when you connect the chassis and the power supplies to the earth ground in the
following ways:
• You connect the chassis (at its grounding pad) to either the data center ground or to a fully bonded and
Installing the Cisco MDS 9396V Switch
14
Slide the fan-tray end of the chassis onto the bottom-support rails so that the chassis locks onto
the chassis stops at the end of the rails.
Chassis stops for holding the chassis (installed by the hot aisle)
Customer-supplied rack-mount screw (M6 x 10 mm screw or other appropriate screw) used to
secure each side of the chassis to the rack.
grounded rack.
Installing the Cisco MDS 9396V Switch