Figure 31
�
�
�
�
Pump �
�
assembly
�
�
Tube #1
�
�
�
�
Rubber �
�
elbows(3)
�
�
�
14. Connect the condensate pump to the ICR relay of
the terminal of the board as shown in Figure 32 &
34 whichever is applicable Make sure to fasten the
pump wire through the wire clip on the back side of
the control barrier as shown in Figure 33.
�
Figure 32
�
�
�
�
�
�
�
�
�
BL
�
�
�
Copyright ©2010 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Spraying �
Tube
Tube #2
BL
15. Assembly the unit back following the reverse order
of disassembly.
NOTE: All tube should be inserted into rubber elbows
by at least 1/2"
Figure 33
Figure 34
- 27 -
LGE Internal Use Only