Figure 8. Disk drive lock detail
5. For a non-RAID drive, configure the installed drive for your environment. If the drive is part of a
RAID configuration, skip this step, the drive is detected and configured when inserted.
After you insert the new drive, you need to rescan for the device.
Ubuntu Linux operating system
To run the rescan-scsi-bus command in the Ubuntu Linux operating system, log in to the
system as the root user, and run the following command:
rescan-scsi-bus
The rescan-scsi-bus tool is available in the scsitools package; install the package by using
the following command:
sudo apt-get install scsitools
Red Hat Enterprise Linux (RHEL) version 7.2
To run the rescan command in the REHL version 7.2 operating system, log in to the system as
the root user, and run the command:
rescan-scsi-bus.sh -a
The rescan-scsi-bus tool is available in the sg3_utils package; install the package by using the
following command:
yum install sg3_utils
You can also want to refer to: Adding a Storage Device or Path(https://access.redhat.com/
documentation/en-US/Red_Hat_Enterprise_Linux/7/html/Storage_Administration_Guide/
logical-unit-add-remove.html).
6. Load or restore data from your backup media.
Removing a drive on module from the 9006-12C system
Learn how to remove a drive on module (DOM) from the IBM Power System LC922 (9006-22C) system.
Removing and replacing parts in the 9006-12C
9