Appendix A
A.1 Ex px safety equipment
Purging unit consisting of:
Explosion protection
Device group
FS870S: Ex type of protection
SR852: Ex type of protection
SR853: Ex type of protection
Installation
Parameters FS870S
Menu
Structure
Parameter
Codes
116
FS870S with SVP2
SR852
SR853
pressure regulator
II 2G / II 2D
II 2 G Ex e db mb ib [pxb] IIC T4 Gb
II 2 D Ex tb IIIC T100°C [ib] [pxb] Db
ATEX: BVS 10 ATEX E 112
IECEx: IECEx BVS 10.0095
II 2 G Ex eb mb IIC T4 Gb
II 2 D Ex tb IIIC T130°C Db
ATEX: BVS 17 ATEX E 016X
IECEx: IECEx BVS 17.0006X
II 2 G Ex eb qb IIC T4 II
2 D Ex tb IIIC T108°C
ATEX: TÜV 02 ATEX 1824
IECEx: IECEx TUN 14.0029
Within Ex area Zone 1/21
Parameter
Language
Valve
Operation
Signaling contact
NO contact/NC contact
Ext. alarm mode
ES872
Purge volume
Nominal pressure purging
Min. flow rate purging
Setpoint flow rate purging
Setpoint pressure operation
Min. flow rate operation
Setpoint flow rate operation
Min. pressure
Max. pressure
Alarm pressure
M code
By code
Compact Operating Instructions, 11/2019, A5E35134047-04
Setting/Value
English
SVP2
Continuous purging
Bypass
NO contact
Inactive
No
10 x 60 l = 600 l
50 mbar
1.0 ls
1.2 l/s
20 mbar
0.02 l/s
0.07 l/s
1 mbar
100 mbar
-
1968
0002