hit counter script

Advertisement

Available languages

Available languages

Quick Links

SPLIT-TYPE AIR CONDITIONERS
INDOOR UNIT
MSY-KT09VF MSY-KT13VF MSY-KT15VF MSY-KT18VF
MSY-KT24VF
www.ttair.co.th | Tel : 02-385-0728 | E-mail : sales@ttair.co.th | LINE ID : @ttair
OPERATING INSTRUCTIONS
• To use this unit correctly and safely, be sure to read these operating
instructions before use.
For user
English

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric Mr. Slim MSY-KT09VF

  • Page 1 SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT MSY-KT09VF MSY-KT13VF MSY-KT15VF MSY-KT18VF For user OPERATING INSTRUCTIONS English MSY-KT24VF • To use this unit correctly and safely, be sure to read these operating instructions before use. www.ttair.co.th | Tel : 02-385-0728 | E-mail : sales@ttair.co.th | LINE ID : @ttair...
  • Page 2: Table Of Contents

    ● OPERATING INSTRUCTIONS ● ONTENTS ■ SAFETY PRECAUTIONS ■ NAME OF EACH PART ■ PREPARATION BEFORE OPERATION ■ SELECTING OPERATION MODES ■ FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT ■ FAST COOLING OPERATION ■ TIMER OPERATION (ON/OFF TIMER) ■ EMERGENCY OPERATION ■...
  • Page 3 AFETY PRECAUTIONS Meanings of symbols used in this manual : Be sure not to do. : Danger of electric shock. Be careful. : Be sure to disconnect the power supply plug : Be sure to follow the instruction. from the power outlet. : Never insert your finger or stick, etc.
  • Page 4 ● OPERATING INSTRUCTIONS ● AFETY PRECAUTIONS WARNING The user should never attempt to wash the inside of the indoor unit. Should the inside of the unit require cleaning, contact your dealer. • Unsuitable detergent may cause damage to plastic material inside the unit, which may result in water leakage.
  • Page 5 AFETY PRECAUTIONS CAUTION Ensure that the area is well-ventilated when the unit is operated together with a combustion appliance. • Inadequate ventilation may cause oxygen starvation. Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike. •...
  • Page 6: Name Of Each Part

    ● OPERATING INSTRUCTIONS ● AME OF EACH PART Indoor unit <KT09/13/15/18> Air inlet (up side) Front panel Air filter (Nano platinum filter) Air cleaning filter (Electrostatic anti-allergy enzyme filter, option) (Microparticle catching filter, Operation indicator lamp Horizontal vane option) Air outlet Remote control receiving section Heat exchanger Emergency operation switch...
  • Page 7: Preparation Before Operation

    REPARATION AME OF EACH PART BEFORE OPERATION Remote controller Before operation: Insert the power supply plug into the power outlet and/or turn the breaker on. Signal transmitting section Installing the remote control- Distance of signal : About 6 m Beep(s) is (are) heard from the ler batteries indoor unit when the signal is received.
  • Page 8: Selecting Operation Modes

    ● OPERATING INSTRUCTIONS ● ELECTING OPERATION MODES Note: Operation indicator lamp The operation indicator lamp shows the operation state of the unit. Room Indication Operation state temperature KT09/13/ KT24 The unit is oper- About 2°C or 15/18 ating to reach the more away from set temperature set temperature...
  • Page 9: Fan Speed And Airflow Direction Adjustment

    AN SPEED AND AIRFLOW DIRECTION ADJUSTMENT Up-down Airflow direction Press to select airflow direc- tion. Each press changes airflow direction in the following order: (AUTO) (SWING) (AUTO) ..The vane is set to the most efficient airflow direction. :horizontal position. (Manual) ..For efficient air conditioning, select the upper position for COOL/DRY, and the lower position for FAN.
  • Page 10: Fast Cooling Operation

    ● OPERATING INSTRUCTIONS ● IMER OPERATION AST COOLING OPERATION (ON/OFF TIMER) Press during operation to set Press during COOL the timer. mode page 7 to start FAST COOL- Each press changes timer mode in ING operation. the following order: Fan speed : Exclusive speed for FAST TIMER COOLING mode...
  • Page 11: Emergency Operation

    MERGENCY OPERATION When the remote controller cannot be used... Emergency operation can be activated by pressing the emergency operation switch (E.O. SW) on the indoor unit. Each time the E.O. SW is pressed, the operation changes in the following order: Operation indicator lamp <KT09/13/15/18>...
  • Page 12: Cleaning

    ● OPERATING INSTRUCTIONS ● LEANING Instructions: • Switch off the power supply or turn off the breaker before cleaning. • Be careful not to touch the metal parts with your hands. • Do not use benzine, thinner, polishing powder, or insecticide. •...
  • Page 13 LEANING Air filter (Nano platinum filter) Clean every 2 weeks • • Remove dirt by a vacuum cleaner, or rinse with water. • After washing with water, dry it well in shade. What is “Nano platinum filter” ? Nano platinum is a ceramic particle that includes a platinum nanoparticle. The particles are incorporated into the filter material, which results in providing semi-permanent antibacterial and deodorizing characteristics for the filter.
  • Page 14: When You Think That Trouble Has Occurred

    ● OPERATING INSTRUCTIONS ● HEN YOU THINK THAT TROUBLE HAS OCCURRED Even if these items are checked, when the unit does not recover from the trouble, stop using the air condi- tioner and consult your dealer. Symptom Explanation & Check points Indoor Unit The unit cannot be operated.
  • Page 15 HEN YOU THINK THAT TROUBLE HAS OCCURRED Symptom Explanation & Check points Does not cool The room cannot be cooled sufficiently. • Is the temperature setting appropriate? Page 7 • Is the fan setting appropriate? Please change fan speed to High or Super High.
  • Page 16: Error Code Display Mode

    ● OPERATING INSTRUCTIONS ● RROR CODE DISPLAY MODE Error code can be checked on the display of remote controller while the left/upper operation indicator lamp on the indoor unit is blinking. Follow the procedure below to check the error code. Error code check Press to change an error code.
  • Page 17 RROR CODE DISPLAY MODE Error code of remote controller Object Code Abnormal point None (Normal) Indoor unit Serial signal Indoor control system Room temperature thermistor Indoor coil thermistor Indoor fan motor Outdoor unit Indoor/outdoor communication, receiving error Nonvolatile memory data Different voltage 4-way valve/Pipe temperature Outdoor refrigerant system...
  • Page 18: When The Air Conditioner Is Not Going To Be Used For A Long Time

    ● OPERATING INSTRUCTIONS ● HEN THE AIR CONDITIONER IS NOT NSTALLATION PLACE GOING TO BE USED FOR A LONG TIME AND ELECTRICAL WORK Installation place Operate by COOL mode with the Avoid installing the air conditioner in the following highest temperature set or FAN places.
  • Page 19: Specifications

    PECIFICATIONS Model MSY-KT09VF MSY-KT13VF MSY-KT15VF Indoor 280 × 838 × 235 280 × 838 × 235 280 × 838 × 235 Dimensions H × W × D (mm) Outdoor 454 × 660 × 235 454 × 660 × 235 538 × 699 × 249 Indoor Weight (kg) Outdoor...
  • Page 20 คู ่ ม ื อ การใช้ ง าน สารบั ญ ข้ อ ควรระวั ง เพื ่ อ คว�มปลอดภั ย ■ ชื ่ อ ของส่ ว นประกอบต่ � งๆ ■ ก�รเตรี ย มตั ว ก่ อ นใช้ ง �น ■ ก�รเลื อ กโหมดก�รใช้ ง �น ■...
  • Page 21 ข้ อ ควรระวั ง เพื ่ อ ความปลอดภั ย ความหมายของสั ญ ลั ก ษณ์ ท ี ่ ใ ช้ ใ นคู ่ ม ื อ ฉบั บ นี ้ : ระวั ง อั น ตร�ยจ�กก�รถู ก ไฟดู ด : ห้ � มปฏิ บ ั ต ิ โ ดยเด็ ด ข�ด : ควรปฏิ...
  • Page 22 คู ่ ม ื อ การใช้ ง าน ข้ อ ควรระวั ง เพื ่ อ ความปลอดภั ย คำ า เตื อ น ผู ้ ใ ช้ ง านไม่ ค วรพยายามล้ า งเครื ่ อ งปรั บ อากาศภายในบ้ า นด้ ว ยตนเอง หากจำ า เป็ น ต้ อ งทำ า ความสะอาดภายในตั ว เครื ่ อ ง โปรดติ...
  • Page 23 ข้ อ ควรระวั ง เพื ่ อ ความปลอดภั ย ข้ อ ควรระวั ง ควรตรวจให้ แ น่ ใ จว่ า พื ้ น ที ่ น ั ้ น จะมี ก ารระบายอากาศที ่ ด ี ข ณะที ่ เ ครื ่ อ งปรั บ อากาศทำ า งานพร้ อ มกั บ เครื ่ อ งใช้ ท ี ่ ม ี ก ารเผาไหม้ •...
  • Page 24 คู ่ ม ื อ การใช้ ง าน ชื ่ อ ของส่ ว นประกอบต่ า งๆ เครื ่ อ งภายในบ้ า น <KT09/13/15/18> ช่ อ งลมเข้ � (ด้ � นบน) ฝ�ครอบด้ � นหน้ � แผ่ น กรองอ�ก�ศ (แผ่ น กรองน�โนแพลติ น ั ม ) แผ่...
  • Page 25 ชื ่ อ ของส่ ว นประกอบต่ า งๆ การเตร ี ย มต ั ว ก ่ อ นใช ้ ง าน รี โ มทคอนโทรล ก่ อ นใช้ ง าน: เสี ย บปลั ๊ ก ไฟเข้ � กั บ เต้ � รั บ และ/หรื อ สั บ เบรกเกอร์ ข ึ ้ น การใส่...
  • Page 26 คู ่ ม ื อ การใช้ ง าน การเลื อ กโหมดการใช้ ง าน หมายเหตุ : ไฟแสดงการทำ า งาน ไฟแสดงก�รทำ � ง�นจะแสดงสถ�นะก�รทำ � ง�นของเครื ่ อ งปรั บ อ�ก�ศ ก�รแสดงก�รทำ � ง�น สถ�นะก�รทำ � ง�น อุ ณ หภู ม ิ ห ้ อ ง KT09/13/ KT24 เครื...
  • Page 27 การปรั บ ทิ ศ ทางและความเร็ ว ของลม ทิ ศ ทางลมขึ ้ น -ลง กดปุ  ม เพื ่ อ เลื อ กทิ ศ ท�งลม เมื ่ อ กดปุ  ม แต่ ล ะครั ้ ง ทิ ศ ท�งลมจะเปลี ่ ย นไปต�มลำ � ดั บ ดั...
  • Page 28 คู ่ ม ื อ การใช้ ง าน การตั ้ ง เวลาเปิ ด /ปิ ด เครื ่ อ ง การทํ า งานแบบ FAST COOLING (การตั ้ ง เวลา ON/OFF) กด ขณะอยู ่ ใ นโหมด COOL หน้ � 7 กด ในระหว่ � งก�รทำ � ง�นเพื ่ อ ตั ้ ง เวล� เพื...
  • Page 29 ระบบการทํ า งานฉุ ก เฉิ น เมื ่ อ ไม่ ส ามารถใช้ ง านรี โ มทคอนโทรล ได้ ... ท่ � นส�ม�รถใช้ ร ะบบก�รทำ � ง�นฉุ ก เฉิ น ได้ โ ดยก�รกดสวิ ต ช์ ก �รทำ � ง�นฉุ ก เฉิ น (E.O. SW) ที ่ เ ครื ่ อ งภ�ยในบ้ � น แต่...
  • Page 30 คู ่ ม ื อ การใช้ ง าน การทํ า ความสะอาด คำ า แนะนำ า : • ปิ ด สวิ ต ช์ แ หล่ ง จ่ � ยไฟ หรื อ สั บ เบรกเกอร์ ล งก่ อ นทำ � คว�มสะอ�ด • ระวั ง อย่ � สั ม ผั ส ชิ ้ น ส่ ว นที ่ เ ป็ น โลหะด้ ว ยมื อ เปล่ � •...
  • Page 31 การทํ า ความสะอาด แผ่ น กรองอากาศ (แผ่ น กรองนาโนแพลติ น ั ม ) ทำ า ความสะอาดทุ ก 2 สั ป ดาห์ • กำ � จั ด สิ ่ ง สกปรกด้ ว ยเครื ่ อ งดู ด ฝุ  น หรื อ ล้ � งออกด้ ว ยนำ ้ � •...
  • Page 32 คู ่ ม ื อ การใช้ ง าน เมื ่ อ ท่ า นคิ ด ว่ า เครื ่ อ งปรั บ อากาศของท่ า นมี ป ั ญ หา หากตรวจสอบทุ ก ข้ อ แล้ ว แต่ ต ั ว เครื ่ อ งยั ง ทำ า งานไม่ ป กติ ให้ ห ยุ ด การใช้ ง านและปรึ ก ษาตั ว แทนจำ า หน่ า ย อาการ...
  • Page 33 เมื ่ อ ท่ า นคิ ด ว่ า เครื ่ อ งปรั บ อากาศของท่ า นมี ป ั ญ หา อาการ รายละเอี ย ดและจุ ด ตรวจสอบ อากาศไม่ เ ย็ น เครื ่ อ งปรั บ อ�ก�ศทำ � คว�มเย็ น ไม่ เ พี ย งพอ •...
  • Page 34 คู ่ ม ื อ การใช้ ง าน โหมดแสดงรหั ส ความผิ ด ปกติ สามารถตรวจสอบรหั ส ความผิ ด ปกติ บ นหน้ า จอของรี โ มทคอนโทรลได้ ใ นขณะที ่ ไ ฟ แสดงการท� า งานด้ า นซ้ า ย/บนของตั ว เครื ่ อ งภายในบ้ า นก� า ลั ง กะพริ บ ทำ...
  • Page 35 โหมดแสดงรหั ส ความผิ ด ปกติ รหั ส ความผิ ด ปกติ ข องรี โ มทคอนโทรล ร�ยก�ร รหั ส จุ ด ที ่ ผ ิ ด ปกติ ไม่ ม ี (ปกติ ) เครื ่ อ ง สั ญ ญ�ณแบบอนุ ก รม ภ�ยในบ้ � น ระบบควบคุ...
  • Page 36 คู ่ ม ื อ การใช้ ง าน เมื ่ อ ไม่ ไ ด้ ใ ช้ เ ครื ่ อ งปรั บ อากาศ สถานที ่ ต ิ ด ตั ้ ง และงานทาง เป็ น เวลานาน ด้ า นไฟฟ้ า สถานที ่ ต ิ ด ตั ้ ง ทำ...
  • Page 37 ข้ อ มู ล จํ า เพาะ รุ ่ น MSY-KT09VF MSY-KT13VF MSY-KT15VF ขนาด เครื ่ อ งภายในบ้ า น 280 × 838 × 235 280 × 838 × 235 280 × 838 × 235 สู ง × กว้ า ง × ลึ ก (มม.) เครื...
  • Page 38 HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN VG79Y253H01 www.ttair.co.th | Tel : 02-385-0728 | E-mail : sales@ttair.co.th | LINE ID : @ttair...

Table of Contents