hit counter script

Forward Limit And Reverse Limit - Mitsubishi Electric MELSEC iQ-F FX5 User Manual

Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

Forward limit and reverse limit

When using the servo motor, the forward rotation limit and the reverse rotation limit can be set for the servo amplifier.
To use the DOG search function for OPR, or to set the forward rotation limit or the reverse rotation limit for operations other
than OPR using the CPU module, set the forward rotation limit 1 (LSF) and reverse rotation limit 1 (LSR) for the CPU module
so that these limit switches can be activated before the forward rotation limit 2 or reverse rotation limit 2 of the servo amplifier.
As shown in the following figure, interlock the forward rotation limit 1 (LSF) with the forward limit, and the reverse rotation limit
1 (LSR) with the reverse limit.
rotation limit 2
(Servo amplifier side)
Servo motor
Forward rotation limit 1
Reverse rotation limit 1
The following table lists the corresponding devices. Related devices of axis 4 are available only for the FX5S/FX5U/FX5UC
CPU module.
Name
CPU module
Axis 1
Forward limit
SM5660
Reverse limit
SM5676
Precautions
If the forward rotation limit 1 (LSF) and the reverse rotation limit 1 (LSR) cannot be set, observe the following items:
• Even if forward rotation limit 2 or reverse rotation limit 2 turns on and the servo motor is automatically stopped, the
positioning instruction currently being driven cannot recognize the motor being stopped. Therefore, pulses will be
continuously output until the instruction is deactivated.
• The dog search function cannot be used.
29 POSITIONING CONTROL FUNCTION
370
29.4 Auxiliary Function
Reverse
Reverse
rotation limit 1
(CPU module side)
LSR
Reverse rotation
SM5660
Forward limit (axis 1)
SM5676
Reverse limit (axis 1)
Axis 2
Axis 3
Axis 4
SM5661
SM5662
SM5663
SM5677
SM5678
SM5679
Forward
rotation limit 1
(CPU module side)
LSF
Forward rotation
High-speed pulse input/output module
First module
Second module
Axis 5
Axis 6
Axis 7
SM5664
SM5665
SM5666
SM5680
SM5681
SM5682
Forward
rotation limit 2
(Servo amplifier side)
Third module
Axis 8
Axis 9
Axis 10
SM5667
SM5668
SM5669
SM5683
SM5684
SM5685
Fourth module
Axis 11 Axis 12
SM5670
SM5671
SM5686
SM5687

Advertisement