hit counter script

LG THERMA V HU123MRB Installation Manual page 260

Air-to-water heat pump
Hide thumbs Also See for THERMA V HU123MRB:
Table of Contents

Advertisement

INSTALLER SETTING
260
- Setting range: Celsius
- Seasonal Auto Driving mode: Heating, Heating & Cooling
* If heating mode is selected, heating & cooling or cooling can not be selected.
- Depending on the air / outflow control selection value, the water / air related setting value is
displayed on the screen.
In this mode, setting temperature will follow outdoor temperature automatically. This mode adds
the cooling season function to the conventional weather dependent operation mode.
Auto-Adjustable
Target Temperature
Water Temp Target: LW/EW1
Room Air Temp Target: RA1
Water Temp Target: LW/EW2
Room Air Temp Target: RA2
Water Temp Target: LW/EW3
Room Air Temp Target: RA3
Water Temp Target: LW/EW4
Room Air Temp Target: RA4
NOTE
DHW mode can be operated independently of seasonal auto temp mode.
of weather dependent operation
Out1
Out2
Temperature profile
Out3
Heating
Cooling
Outdoor air
temperature
Out4

Advertisement