214

Add Zone

Function to set whether or not to use a installed 2nd circuit function using mixing kit.
You can set valve closing time[s] and hysteresis temperature[°C] on screen by yourself.
Value
Default
Range
Valve Closing Time
240 s
60 ~ 999 s
Hysteresis
2 °C
1 ~ 5 °C
Activating this function, It allows 2 zones(Room1, Room2) temperature to be controlled,
separately.
- In case of heating, the temperature of Room1 can not be set higher than Room2 temperature.
- In case of cooling, the temperature of Room1 can not be set lower than Room2 temperature.