QD75D2 and RD75D2
: Compatible : Partly changed : Incompatible : Not applicable
Item
No. of control axes
Interpolation function
Control system
Control unit
Positioning data
Backup
Positioning
Positioning
system
Positioning
range
Speed
command
Acceleration/
deceleration
process
Acceleration/
deceleration
time
Sudden stop
deceleration
time
8 POSITIONING MODULE AND PULSE I/O MODULE MIGRATION
290
8.2 Comparison of Positioning Module and Pulse I/O Module Specifications
Specifications
QD75D2
2
2-axis linear interpolation, 2-axis circular interpolation
PTP (Point To Point) control, path control (all of linear and circular can
be set), speed control, speed-position switching control, position-speed
switching control
mm, inch, degree, pulse
600 data/axis
Parameters, positioning data, and
block start data can be saved on
the flash ROM (battery-less
backup).
PTP control: Incremental system/absolute system
Speed-position switching control: Incremental system/absolute system
Position-speed switching control: Incremental system
Path control: Incremental system/absolute system
In absolute system
-214748364.8 to 214748364.7m, -21474.83648 to 21474.83647 inch,
0 to 359.99999 degree, -2147483648 to 2147483647 pulse
In incremental system
-214748364.8 to 214748364.7m, -21474.83648 to 21474.83647 inch,
-21474.83648 to 21474.83647 degree, -2147483648 to 2147483647
pulse
In speed-position switching control (INC mode)/position-speed
switching control
0 to 214748364.7m, 0 to 21474.83647 inch,
0 to 21474.83647 degree, 0 to 2147483647 pulse
In speed-position switching control (ABS mode)
0 to 359.99999 degree
0.01 to 20000000.00 mm/min
0.001 to 2000000.000 inch/min
0.001 to 2000000.000 degree/min
1 to 1000000 pulse/s
Trapezoidal acceleration/deceleration, S-curve acceleration/
deceleration
1 to 8388608ms (Four patterns can be set for each of acceleration time
and deceleration time.)
1 to 8388608ms
RD75D2
The following save destination
can be selected for positioning
data and block start data.
• CPU module
• Flash ROM of the positioning
module (battery-less)
0.01 to 20000000.00 mm/min
0.001 to 2000000.000 inch/min
0.001 to 3000000.000 degree/min
1 to 5000000 pulse/s
Compatibility
Precautions
The timing at which the
backup data is reflected to the
buffer memory is different. To
change the parameters,
positioning data, and block
start data via a program, do it
after confirming that Module
access flag (X1) has turned
on.