Chapter 40
Configuring Enhanced Object Tracking
Command
Step 6
delay {up seconds [down seconds]
| [up seconds] down seconds}
Step 7
end
Step 8
show track object-number
Step 9
copy running-config
startup-config
This example configures the tracking of an interface line-protocol state and verifies the configuration:
Switch(config)# track 33 interface gigabitethernet0/1 line-protocol
Switch(config-track)# end
Switch# show track 33
Track 33
Interface GigabitEthernet1/0/1 line-protocol
Line protocol is Down (hw down)
Configuring a Tracked List
You can configure a tracked list of objects with a Boolean expression, a weight threshold, or a percentage
threshold. A tracked list contains one or more objects. An object must exist before it can be added to the
tracked list.
•
•
•
OL-9639-07
Purpose
(Optional) Specify a period of time in seconds to delay communicating state
changes of a tracked object. The range is from 1 to 180 seconds.
Return to privileged EXEC mode.
Verify that the specified objects are being tracked.
(Optional) Save your entries in the configuration file.
1 change, last change 00:18:28
You configure a Boolean expression to specify calculation by using either "AND" or "OR"
operators.
When you measure the tracked list state by a weight threshold, you assign a weight number to each
object in the tracked list. The state of the tracked list is determined by whether or not the threshold
was met. The state of each object is determined by comparing the total weight of all objects against
a threshold weight for each object.
When you measure the tracked list by a percentage threshold, you assign a percentage threshold to
all objects in the tracked list. The state of each object is determined by comparing the assigned
percentages of each object to the list.
Cisco ME 3400 Ethernet Access Switch Software Configuration Guide
Configuring Enhanced Object Tracking Features
40-3