Chapter 26
Administering the Switch
Reset scheduled for 23:00:00, Sat Aug 18 2001 (in 0 day 8 hours 39 minutes).
Console> (enable)
This example shows how to schedule a reset with a minimum of downtime:
Console> (enable) reset mindown at 23:00 08/18 Software upgrade to 6.3(1)
Reset scheduled at 23:00:00, Sat Aug 18 2001.
Reset reason: Software upgrade to 6.3(1).
Proceed with scheduled reset? (y/n) [n]? y
Reset mindown scheduled for 23:00:00, Sat Aug 18 2001 (in 0 day 8 hours 39 minutes).
Console> (enable)
Scheduling a Reset Within a Specified Amount of Time
You can schedule a reset within a specified time with the reset in command. For instance, if the current
system time is 9:00 a.m. and the reset is scheduled to take place in one hour, the scheduled reset will
take place at 10:00 a.m. If you or NTP advances the system clock to 10:00 a.m., the reset will take place
at 11:00 a.m. If the clock is advanced ahead of the scheduled reset time, the reset will take place
5 minutes after the command is issued.
To schedule a reset within a specified time, peform this task in privileged mode:
Task
Step 1
Schedule the reset time within a specific amount
of time.
Step 2
Verify that the scheduled reset time is correct.
The minimum downtime argument is valid only if the system has a redundant supervisor engine.
Note
This example shows how to schedule a reset in a specified time:
Console> (enable) reset in 5:20 Configuration update
Reset scheduled in 5 hours 20 minutes.
Reset reason: Configuration update
Proceed with scheduled reset? (y/n) [n]? y
Reset scheduled for 19:56:01, Wed Aug 18 1999 (in 5 hours 20 minutes).
Reset reason: Configuration update
Console> (enable)
Power Management
This section describes power management in the Catalyst 4006 switch and includes the following major
sections:
•
•
The power management feature is designed to support an optimized Catalyst 4006 chassis consisting of
a WS-X4013 supervisor engine and four WS-X4148-RJ or WS-X4148-RJ21 modules operating in 1+1
redundancy mode. Additional configurations are possible.
78-12647-02
Power Redundancy, page 26-12
Setting the Power Budget, page 26-15
Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4
Command
reset [mindown] in [hh] {mm} [reason]
show reset
Power Management
26-11