Removing and Installing the DC-Input Power Supplies
Figure 4-28
If the power supply bay is to remain empty, install a blank power supply filler plate (Cisco part number
Step 9
700-03104-01) over the opening, and secure it with the captive installation screw.
Installing a 4000 W DC-Input Power Supply
The 4000 W DC-input power supply can be wired for either 2700 W or 4000 W operation. The type of
power output from the power supply determines the number of source DC power cables and how they
are routed and connected in the chassis. Refer to
procedure for your site.
Table 4-2
If you are wiring the
4000 W power supply
for...
2700 W operation
2700 W operation
4000 W operation
4000 W operation
Catalyst 6500 Series Switches Installation Guide
4-40
Handling a 4000 W DC-Input Power Supply
I
0
INPU T OK
FAN
OUTP UT
1
2
3
OK
FAIL
4000 W DC-Input Power Supply Installation Options
And you are installing...
A single 4000 W power supply
in the left power supply bay
A redundant (second) 4000 W
power supply in the right power
supply bay
A single 4000 W power supply
in the left power supply bay
A redundant (second) 4000 W
power supply in the right power
supply bay
Chapter 4
Removal and Replacement Procedures
Table 4-2
to select the appropriate installation
Use this procedure
"Installing the 4000 W Power Supply
(Wiring for 2700 W Operation; Left
Power Bay)" section on page 4-42
"Installing the 4000 W Power Supply
(Wiring for 2700 W Operation; Right
Power Bay)" section on page 4-46
"Installing the 4000 W Power Supply
(Wiring for 4000 W Operation; Left
Power Bay)" section on page 4-50
"Installing the 4000 W Power Supply
(Wiring for 4000 W Operation; Right
Power Bay)" section on page 4-54
OL-5781-08