Troubleshooting Modules
Table E-1
Environmental Monitoring for Supervisor Engine and Switching Modules
Component
Supervisor engine temperature sensor
1
exceeds major threshold
Supervisor engine temperature sensor
exceeds minor threshold
Redundant supervisor engine
temperature sensor exceeds major or
minor threshold
Switching module temperature sensor
exceeds major threshold
Switching module temperature sensor
exceeds minor threshold
1. Temperature sensors monitor key supervisor engine components including daughter cards.
2. A STATUS LED is located on the supervisor engine front panel and all module front panels.
3. The STATUS LED is red on the failed supervisor engine. If there is no redundant supervisor, the SYSTEM LED is red also.
Refer to the Catalyst 6500 Series Switch Software Configuration Guide, the Catalyst 6500 Series Switch
Cisco IOS Software Configuration Guide, the Catalyst 6500 Series Switch Command Reference, or the
Catalyst 6500 Series Switch Cisco IOS Command Reference publications to configure or enable the
interfaces. After the system reinitializes the interfaces, the status LED on the module should be green.
If you still experience trouble with the startup, see the
page
Catalyst 6500 Series Switches Installation Guide
E-6
Alarm
Type
LED Indication
Major
STATUS
Minor
STATUS LED
orange
Major
STATUS LED red
Minor
STATUS LED
orange
Major
STATUS LED red
Minor
STATUS LED
orange
E-7.
Action
2
3
LED red
Syslog message and SNMP trap generated.
If redundancy, system switches to redundant
supervisor engine and the active supervisor engine
shuts down.
If there is no redundancy and the overtemperature
condition is not corrected, the system shuts down
after 5 minutes.
Syslog message and SNMP trap generated.
Monitor the condition.
Syslog message and SNMP trap generated.
If major alarm and the overtemperature condition is
not corrected, the system shuts down after 5 minutes.
If minor alarm, monitor the condition.
Syslog message and SNMP trap generated.
Power down the module.
Syslog message and SNMP trap generated.
Monitor the condition.
"Contacting Customer Service" section on
Appendix E
Troubleshooting