hit counter script
Dell PowerEdge C6220 Using Instructions
Dell PowerEdge C6220 Using Instructions

Dell PowerEdge C6220 Using Instructions

Using the baseboard management controller
Hide thumbs Also See for PowerEdge C6220:

Advertisement

Dell PowerEdge C6220
Using the Baseboard
Management Controller
FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC
Manual\BMC\C6220_BMC_HOM_tp.fm
Template Last Updated -03/06/2010

Advertisement

Table of Contents
loading

Summary of Contents for Dell PowerEdge C6220

  • Page 1 Dell PowerEdge C6220 Using the Baseboard Management Controller FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_tp.fm Template Last Updated -03/06/2010...
  • Page 2 © 2012 Dell Inc. All rights reserved. Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell™, the DELL logo, and PowerEdge™ are trademarks of Dell Inc. ® ®...
  • Page 3: Table Of Contents

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_bk0TOC.fm Contents Intelligent Platform Management Interface ......Baseboard Management Controller ... . Supported Platform .
  • Page 4 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_bk0TOC.fm Using the Video Viewer ........Video Viewer Menu IPMI 1.5/2.0 Command Support List .
  • Page 5: Intelligent Platform Management

    BMC is connected to the various sensors through the Intelligent Platform Management Bus (IPMB), a subset of the I2C bus. System software communicates with BMC using a keyboard controller style (KCS) interface. Supported Platform PowerEdge C6220 BMC Key Features and Functions The features supported by BMC are as follows: •...
  • Page 6: Using The Web User Interface

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm • Platform Event Filtering (PEF) to take selected action for selected events • Chassis management, which includes power control, status report, front panel buttons, and LEDs control • Watchdog and auto server re-start and recovery •...
  • Page 7: Logging In To The Web User Interface

    Manual\BMC\C6220_BMC_HOM_section1.fm Logging in to the Web User Interface Users must enter the PowerEdge C6220 embedded server IP address or URL (default DHCP\static IP address) into the address bar of the web browser. When connecting to the PowerEdge C6220 using a web browser, Secure Sockets Layer (SSL) is automatically activated and the display user login form is displayed prompting for the username and password.
  • Page 8 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-1. Default User Name and Password Field Default User Name root Password root NOTE: The default username and password are in lowercase characters. It is advised to change the root password once you have logged in. Click the Help button on the top right corner for assistance.
  • Page 9: Remote Management Controller

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Remote Management Controller The Remote Management Controller menu provides general information about the server including the BMC firmware and network information. Administrators and operators can use this menu to check the sled server health and access all network configuration options. It also provides options for managing security, user access, session status, updating the BMC firmware, and performing remote system shutdown or reboot.
  • Page 10: Properties

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Properties The Properties option enables you to view the remote sled server BMC firmware information. Table 1-2. Firmware Summary Item Description Product Name Sled server system board model name Product Information Remote Management Controller firmware Firmware Version Remote Management Controller firmware version Building Time...
  • Page 11: Chassis

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Chassis The Chassis option enables you to view a summary chassis information including LEDs and power supply status. Table 1-3. Chassis Summary Item Description Chassis Name Server chassis product model name LEDs Server chassis identification and fault LED status PSUs Server chassis power supply(s) status The fan controller board on the server chassis monitors...
  • Page 12: Configuration

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Configuration The Configuration option enables you to view and set values for various system functions. Click on the Configuration option to expand the submenu items. • Network • Security • Users • Services • IPMI Network Select the Network submenu to view and configure the network setting parameters.
  • Page 13 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-4. Network Item Description General Settings Mode Select a network connectivity mode. Host Name Type the name of the BMC host server in this field. DNS Domain Name Type the domain name of the DNS server in this field. Network Interface Configuration Name Column Indicates the network interface name.
  • Page 14 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Security Select the Security submenu to view server certificate information. Secure server certificates ensure the identity of a remote system and ensure that information exchanged with the remote system cannot be viewed or changed by others. Users with administrator or operator privileges can create a Certificate Signing Request (CSR) and upload the file to a certifying authority.
  • Page 15 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-5. Security Options Description Issuer Information: Country Code (CC) Country that issued the certificate State (S) State that issued the certificate Locality (L) City or location that issued the certificate Organization (O) Name of the institution that issued the certificate Organizational Unit (OU) Unit that issued the certificate Common Name (CN) Certification authority...
  • Page 16 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Users Select the Users submenu to view the list of users authorized to access the system. Administrators can grant any user permission privileges by clicking a user ID number. Table 1-6. Users Item Description Password Policy Check Enables you to improve the security of your passwords Enable Checkbox by enforcing strong password security policies.
  • Page 17 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-6. Users Item Description UserID Column Displays a list of users who can access this BMC If a privilege is assigned to a user, the user ID appears as a hyperlink. State Column Shows the status of each user User Name Column Shows the login name of the user User Role Column...
  • Page 18 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Services Select the Services submenu to view the communication service parameters. Users with administrator or operator privileges can set up this service. Table 1-7. Services Item Description HTTP Port Number Port to use for HTTP-based communication. The default HTTP port number is 80.
  • Page 19 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm IPMI Select the IPMI submenu to view the IPMI-based communication service parameters. Users with administrator or operator privileges can configure the IPMI settings. Table 1-8. IPMI Item Description IPMI Serial Connection Mode Select a mode of communication for the serial interface. Settings •...
  • Page 20 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-8. IPMI Item Description IPMI Settings Enable IPMI Over LAN Enables or disables IPMI over LAN access. Channel Privilege Level Select a user privilege level for IPMI over LAN access. Limit Encryption Key Type the IPMI LAN channel encryption key. NOTE: The encryption key must consist of an even number of hexadecimal characters with a maximum of 20...
  • Page 21: Sessions

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Sessions The Sessions option enables you to view sessions currently running on the system. Table 1-9. Sessions Item Description Session ID Column Shows the number of active sessions or session ID numbers. User Name Column Shows the login name of the user.
  • Page 22: Update

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Update The Update option enables users with administrator or operator privileges to update the sled server’s BMC firmware. The following data is included in the BMC firmware package: • Compiled BMC firmware code and data •...
  • Page 23 CAUTION: Do not attempt a forced firmware upgrade without assistance from Dell Technical Support. Upload Button Use this button to initialize the update process. Updating the BMC Firmware CAUTION: Before beginning the firmware update, download the latest firmware version and save it on your local system.
  • Page 24: Utilities

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm 5 Click Update. When the update is completed, the remote system will reboots automatically. NOTE: When the firmware update is in process, the system will not be available to other users. Utilities The Utilities option enables users with administrator and operator privileges to remotely reboot or reset the BMC firmware.
  • Page 25: Server Information

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Server Information The Server Information menu enables users with administrator and operator privileges to remotely perform a power control operation on the server. The Server Information menu provides access to the following configuration options. • Power •...
  • Page 26 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Control Select the Control submenu to view the server’s power status. Users with administrator and operator privilege can perform a power control operation on the server. Table 1-12. Power Control Item Description Power Status Power Status Displays the server power status.
  • Page 27 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Voltages The Voltages submenu provides information on the server’s sensor readings data as well as event log items. For more information on voltage threshold settings and the conversion equation for the voltage readings, see "Threshold Settings and Converting Formulas"...
  • Page 28 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-13. Voltages Sensor Readings Items Description Lower Non-Recoverable Shows the system board lower non-recoverable threshold Column voltage. Lower Critical Column Shows the system board lower critical threshold. Lower Non-Critical Shows the system board lower non-critical threshold. Column Upper Non-Critical Shows the system board upper non-critical threshold.
  • Page 29 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Supplies Select the Supplies submenu to view the status of the server chassis’s power supply. The power supplies are shared among all the sled servers in the server chassis. Click the Chassis option on the menu bar to view detailed information about the server chassis power supply.
  • Page 30 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Batteries The Batteries submenu enables you to view the status of the server system board battery. Table 1-15. Batteries Status Item Description Status Column This column shows the system board CMOS coin-cell battery status. Probe Name Column This column shows the name of the battery sensor.
  • Page 31: Thermal

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Thermal The Thermal option enables you to view the server fan and temperature sensor readings. Click on the Thermal option to expand the submenu items. • Fans • Temperatures Fans Select the Fans submenu to view the status and readings of the server fan sensors.
  • Page 32 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-16. Fans Sensor Readings Items Description Lower Critical Column Displays the fan lower critical threshold. Lower Non-Critical Column Displays the fan lower non-critical threshold. Upper Non-Critical Column Displays the fan upper non-critical threshold. Upper Critical Column Displays the fan upper critical threshold.
  • Page 33 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Temperatures Select the Temperatures submenu to view the status and readings of the server temperature sensors. For more information on temperature threshold settings and the conversion equation for the temperature readings, see "Threshold Settings and Converting Formulas" on page 66. Table 1-17.
  • Page 34 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-17. Temperature Sensor Readings Items Description Lower Non-Recoverable Displays the temperature sensor lower non-recoverable Column threshold. Lower Critical Column Displays the temperature sensor lower critical threshold. Lower Non-Critical Displays the temperature sensor lower non-critical Column threshold.
  • Page 35: System Event Log

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm System Event Log The System Event Log menu enables users with administrator and operator privileges to view system event information such as event ID, time stamp, sensor name, sensor type, and description (Event Log button). Table 1-18.
  • Page 36: Event Management

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Event Management The Event Management option enables users with administrator or operator privilege to configure the Platform Event Filter (PEF) filters, SNMP trap settings, and email notifications. Click on the Event Management option to expand the submenu items. •...
  • Page 37 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-19. Platform Event Filters Items Description Filter Name Column This column lists the platform event filters. • Fan Critical Assert filter • Battery Warning Assert filter • Battery Critical Assert filter • Discrete Voltage Critical Assert filter •...
  • Page 38 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Trap Settings Select the Trap Settings submenu to view and manage the Simple Network Management Protocol (SNMP) trap events. Table 1-20. Trap Settings Items Description IPv4 Destination List Enable Checkbox Enables or disables an IPv4 destination address. You can enable up to four IPv4 destination addresses.
  • Page 39 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-20. Trap Settings Items Description Community String Community Name View or modify the SNMP community name. Apply Changes Button Use this button to apply the changes.
  • Page 40 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Email Settings Select the Email Settings submenu to view email settings. Users with administrator or operator privileges can set email addresses for sending alert notifications. Table 1-21. Email Settings Items Description Destination Email Addresses Enable Checkbox Enables or disables an email alert notification.
  • Page 41 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-21. Email Settings Items Description Username Specifies a username for an authenticated sendmail. Password Specifies a password for an authenticated sendmail. STARTTLS mode Select a Start Transport Layer Security (StartTLS) mode. SASL Mode Select a Simple Authentication and Security Layer (SASL) authentication mode.
  • Page 42: Serial Over Lan

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Serial Over LAN The Serial over LAN menu enables users with administrator and operator privileges to configure the Serial over LAN settings, select or change pertinent values for each attribute and save any changes. Table 1-22. Serial Over LAN Settings Items Description Enable Serial Over LAN...
  • Page 43: Vkvm & Vmedia

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm vKVM & vMedia The vKVM & vMedia option enables the administrators to view and configure the virtual KVM and media settings and launch the Java KVM and VM console clients. Click on the vKVM & vMedia option to expand the submenu items. •...
  • Page 44 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-23. Virtual KVM and Media Launch Settings Items Description Video Encryption Video encryption status Enabled Preferred Client Type Client application used for connecting to the KVM client Virtual Media Configuration Max Sessions Maximum number of console redirection sessions allowed Active Sessions Number of active console sessions...
  • Page 45 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm To start a remote console session from the Virtual KVM and Media Launch window, click the Launch Java KVM Client or Launch Java VM Client button. This launches the redirection console via the JViewer Java applet. For further information on remote console sessions, see "Using the Video Viewer"...
  • Page 46 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-24. Virtual KVM and Media Configuration Items Description Preferred Client Type Select a client application to use for connecting to the KVM client. Virtual Media Configuration Encryption Enabled Enables or disables the virtual media. Preferred Client Type Select a client application to use for connecting to the VM client.
  • Page 47: Using The Video Viewer

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Using the Video Viewer The Video Viewer provides a user interface between the management station and the managed server, allowing you to see the managed server's desktop and control its mouse and keyboard functions from your management station. When you connect to the remote system, the Video Viewer login screen prompts for the password.
  • Page 48: Video Viewer Menu

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Video Viewer Menu The Video Viewer menu provides access to additional functions, outlined in the following tables. Table 1-25. File Menu Items Menu Option Description Capture to File Captures the current remote system screen to save it as a file. Exit Closes the Video Viewer window.
  • Page 49 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-28. Tools Menu Items Menu Option Description Instant Messaging Sends a real-time message to another console user. Sessions Options Provides additional session viewer control adjustments. The General tab allows you to enable the keyboard pass through mode feature.
  • Page 50 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-30. Help Menu Items Menu Option Description Contents and Index Opens the Video Viewer Help. About Displays the Video Viewer version information.
  • Page 51: Ipmi 1.5/2.0 Command Support List

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm IPMI 1.5/2.0 Command Support List The IPMItool program provides a simple command-line interface for managing IPMI-enabled devices. The IPMItool enables you to read the BMC devices, BMC watchdog timer, PEF/PET alerts, SDR, events, SEL, FRU information, serial/modem devices, set LAN configuration parameters, update the BMC firmware remotely and perform remote server chassis or sled server power control.
  • Page 52 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-31. IPMI Device Global Commands (NETFUN: 06H) Command NetFn Supported Get Device ID Broadcast Get Device ID Cold Reset Warm Reset Get Self Test Results Manufacture Test On Get ACPI Power State Get Device GUID Get NetFn Support Get Command Support Get Command Sub-function Support...
  • Page 53 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-32. BMC Device and Messaging Commands (NETFUN: 06H) Command NetFn Supported Set BMC Global Enables Get BMC Global Enables Clear Message Buffer Flags Get Message Buffer Flags Enable Message Channel Receive Get Message Send Message Read Event Message Buffer Get BT Interface Capabilities Get System GUID...
  • Page 54 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-33. BMC Device and Messaging Commands (NETFUN: 06H) (continued) Command NetFn Supported Set User Password Commands Active Payload Command Deactivate Payload Command Get Payload Activation Status Get Payload Instance Info Command Set User Payload Access Get User Payload Access Get Channel Payload Support Get Channel Payload Version...
  • Page 55 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-35. Chassis Device Commands (NETFUN: 00H) Command NetFn Supported Get Chassis Capabilities Chassis Get Chassis Status Chassis Chassis Control Chassis Chassis Reset Chassis Chassis Identify Chassis Set Chassis Capabilities Chassis Set Power Restore Policy Chassis Get System Restart Cause Chassis...
  • Page 56 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-37. Sensory Device Commands (NETFUN: 04H) Command NetFn Supported Get Device SDR Info Get Device SDR Reserve Device SDR Repository Get Sensor Reading Factors Set Sensor Hysteresis Get Sensor Hysteresis Set Sensor Threshold Get Sensor Threshold Set Sensor Event Enable Get Sensor Event Enable Set Sensor Reading and Event Status...
  • Page 57 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-39. SEL Commands (NETFUN: 04H) Command NetFn Supported Get SEL Info Storage Get SEL Allocation Info Storage Reserve SEL Storage Get SEL Entry Storage Add SEL Entry Storage Partial Add SEL Entry Storage Delete SEL Entry Storage Clear SEL Storage...
  • Page 58 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-41. SDR Repository Commands (NETFUN: 0AH) Command NetFn Supported Get SDR Repository Info Storage Get SDR Repository Allocation Info Storage Reserve SDR Repository Storage Get SDR Storage Add SDR Storage Partial ADD SDR Storage Delete SDR Storage Clear SDR Repository...
  • Page 59 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-43. Serial/Modem Device Commands (NETFUN: 0CH) Command NetFn Supported Set Serial/Modem Configuration Transport 10h Get Serial/Modem Configuration Transport 11h Set Serial/Modem Mux Transport 12h Get TAP Response Codes Transport 13h Set PPP UDP Proxy Transmit Data Transport 14h Get PPP UDP Proxy Transmit Data Transport 15h...
  • Page 60 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-45. Firmware Update Commands (NETFUN: 08H) Command NetFn Supported Firmware Update Phase 1 Firmware 10h Firmware Update Phase 2 Firmware 11h Get Firmware Update Status Firmware 12h Get Firmware Version Firmware 13h Set Firmware Update Status Firmware 16h Firmware Update Phase 3 Firmware 21h...
  • Page 61: Sensor Summary

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Sensor Summary The following table includes an overview of the system sensors. In the Offset column: • SI = Sensor Initialization • SC = Sensor Capabilities • AM = Assertion Mask • DM = Deassertion Mask •...
  • Page 62 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-47. Sensor Summary (continued) Sensor Sensor Name Sensor Type Event/Reading Type Offset Number CPU ERR2 Processor (07h) Sensor-specific SI: 01h (6Fh) SC: 40h AM: 0001h DM: 0000h RM: 0001h 12 V Standby Voltage (02h) Threshold (01h) SI: 7Fh SC: 59h...
  • Page 63 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-48. Sensor Summary (continued) Sensor Sensor Name Sensor Type Event/Reading Type Offset Number 3.3 V Standby Voltage (02h) Threshold (01h) SI: 7Fh SC: 59h AM: 7A95h DM: 7A95h TM: 3F3Fh Battery low Battery (29h) Sensor-specific SI: 67h (6Fh)
  • Page 64 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-49. Sensor Summary (continued) Sensor Sensor Name Sensor Type Event/Reading Type Offset Number DIMM ZONE 1 Temperature (01h) Threshold (01h) SI: 7Fh Temp SC: 68h AM: 0A80h DM: 0A80h TM: 3838h DIMM ZONE 1 Temperature (01h) Threshold (01h) SI: 7Fh...
  • Page 65 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-50. Sensor Summary (continued) Sensor Sensor Name Sensor Type Event/Reading Type Offset Number Soft Reset System Boot / Sensor-specific SI: 01h Restart Initiated (6Fh) SC: 40h (1Dh) AM: 0004h DM: 0000h RM: 0004h AC lost Power Unit (09h) Sensor-specific SI: 01h...
  • Page 66: Threshold Settings And Converting Formulas

    FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Threshold Settings and Converting Formulas The following table lists the system sensor’s threshold settings and formulas for converting the sensor readings. Table 1-51. Threshold Settings and Converting Formulas Sensor Sensor Name The Converting Formula Number Upper non- Upper Upper...
  • Page 67 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm Table 1-52. Threshold Settings and Converting Formulas (continued) Sensor Sensor Name The Converting Formula Number Upper non- Upper Upper Lower non- Lower Lower recoverable critical non- recoverable critical non- critical critical Temperature MEZZ1 Temp Actual_Reading (degrees C) = Raw_Data - 128 CPU1 Temp Actual_Reading (degrees C) = Raw_Data CPU2 Temp...
  • Page 68 FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm...