Chapter 32
Configuring Ethernet OAM, CFM, and E-LMI
Command
Step 12
continuity-check loss-threshold threshold-value
Step 13
maximum meps value
Step 14
sender-id {chassis | none}
Step 15
mip auto-create [lower-mep-only | none]
Step 16
exit
Step 17
mip auto-create [lower-mep-only]
Step 18
mep archive-hold-time minutes
Step 19
exit
Step 20
interface interface-id
Step 21
switchport mode trunk
Step 22
ethernet cfm mip level level-id
OL-23400-01
Purpose
(Optional) Set the number of continuity check messages to
be missed before declaring that an MEP is down. The range
is 2 to 255; the default is 3.
(Optional) Configure the maximum number of MEPs
allowed across the network. The range is from 1 to 65535.
The default is 100.
(Optional) Include the sender ID TLVs, attributes
containing type, length, and values for neighbor devices.
chassis—Send the chassis ID (host name).
•
none—Do not include information in the sender ID.
•
(Optional) Configure auto creation of MIPs for the service.
lower-mep-only—Create a MIP only if there is a MEP
•
for the service in another domain at the next lower
active level.
•
none —No MIP auto-create.
Return to ethernet-cfm configuration mode.
(Optional) Configure auto creation of MIPs for the domain.
•
lower-mep-only—Create a MIP only if there is a MEP
for the service in another domain at the next lower
active level.
(Optional) Set the number of minutes that data from a
missing maintenance end point is kept before it is purged.
The range is 1 to 65535; the default is 100 minutes.
Return to global configuration mode.
Specify an interface to configure, and enter interface
configuration mode.
(Optional) Configure the port as a trunk port.
(Optional) Configure a customer level or service-provider
level maintenance intermediate point (MIP) for the
interface. The MIP level range is 0 to 7.
This step is not required if you have entered the
Note
ethernet cfm mip auto-create global
configuration command or the mip auto-create
ethernet-cfm or ethernet-cfm-srv configuration
mode.
Cisco ME 3800X and 3600X Switch Software Configuration Guide
Configuring Ethernet CFM