hit counter script

Cisco 3845 - Security Bundle Router Software Manual page 723

Software configuration guide
Hide thumbs Also See for 3845 - Security Bundle Router:
Table of Contents

Advertisement

Chapter 32
Configuring Ethernet OAM, CFM, and E-LMI
Command
Step 4
ethernet oam link-monitor symbol-period
{threshold {high {high symbols | none} | low
{low-symbols}} | window symbols}
Repeat this step to configure both high and
Note
low thresholds.
Step 5
ethernet oam link-monitor frame {threshold {high
{high-frames | none} | low {low-frames}} | window
milliseconds}
Repeat this step to configure both high and
Note
low thresholds.
Step 6
ethernet oam link-monitor frame-period
{threshold {high {high-frames | none} | low
{low-frames}} | window frames}
Note
Repeat this step to configure both high and
low thresholds.
OL-23400-01
Purpose
(Optional) Configure high and low thresholds for an
error-symbol period that trigger an error-symbol period
link event.
Enter threshold high high-symbols to set a high
threshold in number of symbols. The range is 1 to
65535. The default is none.
Enter threshold high none to disable the high
threshold if it was set. This is the default.
Enter threshold low low-symbols to set a low
threshold in number of symbols. The range is 0 to
65535. It must be lower than the high threshold.
Enter window symbols to set the window size (in
number of symbols) of the polling period. The range is
1 to 65535 symbols.
(Optional) Configure high and low thresholds for error
frames that trigger an error-frame link event.
Enter threshold high high-frames to set a high
threshold in number of frames. The range is 1 to
65535. The default is none.
Enter threshold high none to disable the high
threshold if it was set. This is the default.
Enter threshold low low-frames to set a low threshold
in number of frames. The range is 0 to 65535. The
default is 1.
Enter window milliseconds to set the a window and
period of time during which error frames are counted.
The range is 10 to 600 and represents the number of
milliseconds in multiples of 100. The default is 100.
(Optional) Configure high and low thresholds for the
error-frame period that triggers an error-frame-period link
event.
Enter threshold high high-frames to set a high
threshold in number of frames. The range is 1 to
65535. The default is none.
Enter threshold high none to disable the high
threshold if it was set. This is the default.
Enter threshold low low-frames to set a low threshold
in number of frames. The range is 0 to 65535. The
default is 1.
Enter window frames to set the a polling window size
in number of frames. The range is 1 to 65535; each
value is a multiple of 10000 frames. The default is
1000.
Cisco ME 3800X and 3600X Switch Software Configuration Guide
Setting Up and Configuring Ethernet OAM
32-27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Me 3800xMe 3600x

Table of Contents