Asus DS300i User Manual page 390

User manual
Hide thumbs Also See for DS300i:
Table of Contents

Advertisement

Reported Event
Battery capacity is normal Normal.
Battery is discharging
Battery is charging
Battery reconditioning is
complete
Battery is malfunctioning
Battery reconditioned
successfully
Battery reconditioning has
failed
Battery is reaching end of
life
Battery is removed
Battery charging failed
Battery reconditioning
started
Battery recondition
terminated
Blowers
Blowers have started
Blowers have stopped
Blower speed is
increased
Blower speed is
decreased
Blowers are NOT
functioning
Blowers have been
inserted
Battery is undergoing reconditioning.
Battery is being recharged.
Battery reconditioning is finished.
Run battery reconditioning. Run battery
reconditioning. See page 139 (ASUS Storage
Management) or page 220 (CLU). If this message
reappears, replace the battery.
Battery reconditioning is finished.
Replace the battery. See page 314
Replace the battery. See page 314.
The battery was disconnected or removed. Reinstall
the battery. See page 314
Replace the battery. See page 314.
Battery reconditioning has begun.
The battery was disconnected or removed during
reconditioning. Reinstall the battery. See page 314.
Normal.
Verify that the fans are properly installed. If they still
does not turn, replace the fan. See page 313.
Check the ASUS Storage for overheating. See
page 390.
Temporary overheat condition was corrected.
Replace the fans. See page 313.
Normal.
371
Chapter 10: Troubleshooting