Displaying System Status Information for Technical Support
Table 22-2
Component
Supervisor engine
temperature sensor exceeds
major threshold
Supervisor engine
temperature sensor exceeds
minor threshold
Redundant supervisor engine
temperature sensor exceeds
major or minor threshold
Switching module
temperature sensor exceeds
major threshold
Switching module
temperature sensor exceeds
minor threshold
1. The temperature sensors monitor the key supervisor engine components including the daughter cards.
2. A STATUS LED is located on the supervisor engine front panel and all the module front panels.
3. The STATUS LED is red on the failed supervisor engine. If there is no redundant supervisor engine, the SYSTEM LED is
4. See the
Displaying System Status Information for Technical Support
These sections describe how to display the system status information for technical support:
•
•
•
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
22-16
Environmental Monitoring for Supervisor Engine and Switching Modules
1
red also.
"Power Management" section on page 22-12
Generating a System Status Report, page 22-17
Using System Dump Files, page 22-17
Using System Crash-Info Files, page 22-19
Alarm
Type
LED Indication
2
Major
STATUS
LED red
Minor STATUS LED
orange
Major
STATUS LED red
Minor STATUS LED
orange
Major
STATUS LED red
Minor STATUS LED
orange
for instructions.
Chapter 22
Administering the Switch
Action
3
syslog message and SNMP trap
generated.
If redundancy, system switches to the
redundant supervisor engine and the
active supervisor engine shuts down.
If there is no redundancy and the
overtemperature condition is not
corrected, the system shuts down after
5 minutes.
syslog message and SNMP trap
generated.
Monitor the condition.
syslog message and SNMP trap
generated.
If major alarm and the overtemperature
condition is not corrected, the system
shuts down after 5 minutes.
If minor alarm, monitor the condition.
syslog message and SNMP trap
generated.
Power down the module
syslog message and SNMP trap
generated.
Monitor the condition.
4
.
OL-8978-04