hit counter script

Replacing Fan Modules - Cisco UCS C220 Installation And Service Manual

Hide thumbs Also See for UCS C220:
Table of Contents

Advertisement

Installing or Replacing Server Components

Replacing Fan Modules

The five fan modules in the server are numbered as follows when you are facing the front of the server
(also see
Figure 3-10
FAN 1
Tip
Each fan module has a fault LED on the motherboard that lights amber if the fan module fails. Power
must be connected to the server for these LEDs to operate.
To replace or install a hot-pluggable fan module, follow these steps:
Caution
You do not have to shut down or power off the server to replace fan modules because they are hot-
pluggable. However, to maintain proper cooling, do not operate the server for more than one minute with
any fan module removed.
Remove a fan module that you are replacing (see
Step 1
a.
If you cannot safely view and access the component, remove the server from the rack.
Caution
b.
c.
Step 2
Install a new fan module:
a.
b.
c.
d.
Cisco UCS C220 Server Installation and Service Guide
3-16
Figure
3-11).
Fan Module Numbering
FAN 2
Slide the server out the front of the rack far enough so that you can remove the top cover. You might
have to detach cables from the rear panel to provide clearance.
Remove the top cover as described in
page
3-8.
Grasp the fan module and lift straight up to disengage its connector from the motherboard.
Set the new fan module in place, aligning its two rubber dampening gaskets with the openings in the
chassis panel. See
Figure
3-11.
Press down gently on the fan module connector to fully engage it with the connector on the
motherboard.
Replace the top cover.
Replace the server in the rack.
FAN 3
FAN 4
Figure
3-11):
"Removing and Replacing the Server Top Cover" section on
Chapter 3
Maintaining the Server
FAN 5
OL-25760-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ucs c220 m3

Table of Contents