Table 10. Alarm Event Codes and Hex/Binary Values
Event Number Text Message
00
Network address
01
Hardware mismatch
02
Model number not programmed
03
Authorization fault
04
Synthesizer out-of-lock
05
Reserved
06
Peripheral fault or RAM fault
07
Voltage regulator fault detected
08
Radio not calibrated
09
DSP download fault
10
NVRAM fault
11
Reserved
12
Receiver time-out
13
Time out command
14
Reserved
15
Output power fault
16
Unit address not programmed
17
Data parity error
18
Data framing error
19
Reserved
20
Configuration error
21
Running on battery
22
Standby missing
23
Standby has alarms
24
Power output faults
25
6-Volt regulator output not in valid
range
26
DC input power is not in valid
range
27
LNA current fault
22
The eight-digit hexadecimal number used as the command parameter
specifies 0 to 32 events that can trigger the external alarm output (see
Table
10
below for a list of events). The hex value for the mask corre-
sponds to the hex value for the
is a '1' identifies an alarm condition that can trigger the external output.
Alarm Code
(hex)
8000 0000
4000 0000
2000 0000
1000 0000
0800 0000
0200 0000
0100 0000
0080 0000
0040 0000
0020 0000
0008 0000
0004 0000
0001 0000
0000 8000
0000 4000
0000 2000
0000 0800
0000 0400
0000 0200
0000 0100
0000 0080
0000 0040
0000 0020
0000 0010
MDS 4710/9710 Technical Manual
command
(Page
STAT
32-bit Binary Equivalent
1000 0000 0000 0000 0000 0000 0000 0000
0100 0000 0000 0000 0000 0000 0000 0000
0010 0000 0000 0000 0000 0000 0000 0000
0001 0000 0000 0000 0000 0000 0000 0000
0000 1000 0000 0000 0000 0000 0000 0000
0000 0010 0000 0000 0000 0000 0000 0000
0000 0001 0000 0000 0000 0000 0000 0000
0000 0000 1000 0000 0000 0000 0000 0000
0000 0000 0100 0000 0000 0000 0000 0000
0000 0000 0010 0000 0000 0000 0000 0000
0000 0000 0000 1000 0000 0000 0000 0000
0000 0000 0000 0100 0000 0000 0000 0000
0000 0000 0000 0001 0000 0000 0000 0000
0000 0000 0000 0000 1000 0000 0000 0000
0000 0000 0000 0000 0100 0000 0000 0000
0000 0000 0000 0000 0010 0000 0000 0000
0000 0000 0000 0000 0000 1000 0000 0000
0000 0000 0000 0000 0000 0100 0000 0000
0000 0000 0000 0000 0000 0010 0000 0000
0000 0000 0000 0000 0000 0001 0000 0000
0000 0000 0000 0000 0000 0000 1000 0000
0000 0000 0000 0000 0000 0000 0100 0000
0000 0000 0000 0000 0000 0000 0010 0000
0000 0000 0000 0000 0000 0000 0001 0000
MDS 05-3305A01, Rev. E
31). Each bit that