3.1. ADC Process
(1) ADC
- Enter Service Mode by pushing "ADJ" key,
- Enter Internal ADC mode by pushing "►" key at "7. ADC
Calibration".
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option 5
5. Country Group
6. Area Option
7. ADC Calibration
8. White Balance
9. 10 Point WB
10. Test Pattern
11. EDID D/L
12. Sub B/C
13. Touch Sensitivity Setting
<Caution> Using "P-ONLY" key of the Adjustment remote
control, power on TV.
If there is no Component Input, disappear "ADC Comp" message.
* ADC Calibration Protocol (RS232)
NO
Item
CMD 1
Enter
Adjust
A
Adjust MODE
'Mode In'
ADC adjust
ADC Adjust
A
Adjust Sequence
▪ aa 00 00 [Enter Adjust Mode]
▪ xb 00 40 [Component1 Input (480i)]
▪ ad 00 10 [Adjust 480i Comp1]
▪ xb 00 60 [RGB Input (1024*768)] (only LD21B)
▪ ad 00 10 [Adjust 1024*768 RGB] (only LD21B)
▪ aa 00 90 End Adjust mode
* Required equipment : Adjustment remote control.
3.2. Function Check
3.2.1. Check display and sound
■ Check Input and Signal items. (cf. work instructions)
1. TV
2. AV
3. COMPONENT (480i)
4. RGB (PC : 1024 x 768 @ 60hz)
5. HDMI
6. PC Audio In
* Display and Sound check is executed by Remote controller
Caution : Not to push the INSTOP KEY after completion if the
function inspection.
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
ADC Calibration
ADC Comp 480i
NG
ADC Comp 1080p
NG
ADC RGB
NG
Start
Reset
CMD 2
Data 0
When transfer the 'Mode In',
A
0
0
Carry the command.
Automatically adjustment
D
1
0
(The use of a internal pattern)
4. Total Assembly line process
4.1. Adjustment Preparation
▪ W/B Equipment condition
CA210
: CCFL/EEFL -> CH9, Test signal: Inner pattern(80IRE)
LED -> CH14, Test signal: Inner pattern(80IRE)
▪ Above 5 minutes H/run in the inner pattern. ("power on" key
of adjust remote control)
Mode
Temp
Coordinate spec
X=0.269 (±0.002)
Cool
13,000k
Y=0.273 (±0.002)
X=0.285 (±0.002)
Medium
9,300k
Y=0.293 (±0.002)
X=0.313 (±0.002)
Warm
6,500k
Y=0.329 (±0.002)
▪ Edge LED W/B Table in process of aging time (Only LGD
Edge LED Module except AUO, CMI, IPS Module)
CA210 : CH 14, Test signal : Inner pattern (80IRE)
Aging
GP4
time
X
(Min)
269
1
0-2
280
2
3-5
279
3
6-9
277
4
10-19
276
5
20-35
274
6
36-49
272
7
50-79
271
8
80-149
270
9
Over 150
269
* Connecting picture of the measuring instrument
(On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push Adjustment R/C POWER ON →
Enter the mode of White-Balance, the pattern will come out.
Full White Pattern
RS-232C Communication
* Auto-control interface and directions
(1) Adjust in the place where the influx of light like floodlight
around is blocked. (illumination is less than 10 lux).
(2) Adhere closely the Color analyzer(CA210) to the module
less than 10 cm distance, keep it with the surface of the
Module and Color analyzer's prove vertically.(80° ~ 100°).
(3) Aging time
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 5 minutes.
- Using 'no signal' or 'POWER ONLY' or the others, check
the back light on.
- 10 -
Target
X=0.271
Y=0.276
X=0.287
Y=0.296
X=0.315
Y=0.332
Cool
Medium
y
x
y
273
285
293
287
296
307
285
295
305
284
293
304
283
292
303
280
290
300
277
288
297
275
287
295
274
286
294
273
285
293
COLOR
ANALYZER
TYPE : CA-210
LGE Internal Use Only
<Test Signal>
Inner pattern
(204gray,
80IRE)
Warm
x
y
313
329
320
337
319
335
317
334
316
333
314
330
312
327
311
325
310
324
309
323
CA-210