hit counter script

Power Supplies; Dc Power Subsystem; Figure 8. Non-Redundant Ac-Power Supply Subsystem (Filler Module Shown At Left) - IBM @server xSeries 343 Product Manual

Ibm @server xseries 343 server product guide
Table of Contents

Advertisement

Power Supplies

The power supply cage shown in Figure 8 is accessed from the rear of the chassis. The power
supply cage supports up to two hot-swap power supplies (either AC input or DC input) in a (1+1)
redundant configuration. A power supply filler module (shown at left in Figure 8) for the empty
power supply site is supplied for systems without redundancy.
Only the DC input version is NEBS certified.

Figure 8. Non-redundant AC-Power Supply Subsystem (Filler Module Shown at Left)

DC Power Subsystem

This section defines the features of the DC input switching power subsystem.
Features
470-Watt output capability in full DC input voltage range
"Power Good" indication LEDs
Predictive failure warning
Internal cooling fans with multi-speed capability
Remote sense of 3.3-Volt, 5-Volt, and 12-Volt DC outputs
"DC_OK" circuitry for brown-out protection and recovery
Built-in load sharing capability
Built-in overloading protection capability
Onboard field replaceable unit (FRU) information
2
I
C interface for server management functions
Integral handle for insertion/extraction
xSeries 343 Product Guide