hit counter script

Post; Health Check; Event Log; Service Port Commands - IBM TotalStorage DS4000 Hardware Maintenance Manual

Hide thumbs Also See for TotalStorage DS4000:
Table of Contents

Advertisement

POST

POST is divided into two functionally distinct parts: the initial-POST (IPOST) and
the secondary-POST (SPOST)
IPOST is the first stage of POST and it thoroughly tests the on-board, dynamic
random-access memory (DRAM) arrays. IPOST runs from the on-board flash
memory. Upon successful completion, IPOST locates SPOST, copies it to the
DRAM, and then transfers program control to SPOST.
SPOST is the second stage of post. SPOST configures the SDG Router's PCI bus.
SPOST then locates, loads, and runs the licensed internal code.

Health Check

The health check program queries all subsystems for their operational status. The
health check has four levels. A level 1 health check is the most basic, and health
check level 4 is the most complete check.

Event Log

The SDG Router maintains an event log within its on-board flash file system. You
can query these logs from the SDG Router service port. Event codes and messages
that the SDG Router subsystems generate are recorded in this log file.

Service Port Commands

An extensive command set is available to manage the SDG Router, obtain Status,
and run Diagnostics. The commands described in Table 53 have been extracted
from the SDG Service Guide. They provide you with some basic tools to determine
the functional status of the SDG Router. See Appendixes A and B of the SDG
Service Guide for a description of all the commands.
Table 53. SDG Router service port commands
Group
diagBoot
120
IBM TotalStorage DS4000: Hardware Maintenance Manual
Table 52. SDG Router LED indicators (continued)
LEDs (G=Green)
(A=Amber)
Function
Collision (A)
Status
TEMPERATURE
WARNING (A)
Preventive
failure indicator
Alarm (A)
Information
Power Main (G)
Information
Ready (G)
Information
Description
Used to transition the SDG Router from normal operation to Diagnostic mode
(see normalBoot below)
On
Off
Collision
occurred
Temperature
No temperature
Warning
problem
Temperature
No temperature
exceeded
problem
Power applied
No power
SDG Failure if
SDG Failure
on for more than
2 sec.
Flash
N/A
N/A
N/A
Flashes during
Startup cycle
and once every
second
thereafter
(normal)
Page
121

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents